Справочник Пользователя для Hamilton Sundstrand Company Fuel Metering Valves XVG

Скачать
Страница из 36
 
 
 
Register 
Number 
XVG/eXVG Parameter 
Name 
Write 
Access 
Description Type 
Default 
Value 
7544 7545 
IDM_BACKPRES0 
W2
 
Backpressure 0 
Float 
14.7 
7546 7547 
IDM_BACKPRES1 
W2
 
Backpressure 1 
Float
 
64.7 
7548 7549 
IDM_BACKPRES2 
W2
 
Backpressure 2 
Float
 
114.7 
7550 7551 
IDM_BACKPRES3 
W2
 
Backpressure 3 
Float
 
164.7 
7552 7553 
IDM_BACKPRES4 
W2
 
Backpressure 4 
Float
 
214.7 
7554 7555 
IDM_MINFLOWLIM0 
W2
 
Minimum Flow 0 
Float
 
7556 7557 
IDM_MINFLOWLIM1 
W2
 
Minimum Flow 1 
Float
 
200 
7558 7559 
IDM_MINFLOWLIM2 
W2
 
Minimum Flow 2 
Float
 
500 
7560 7561 
IDM_MINFLOWLIM3 
W2
 
Minimum Flow 3 
Float
 
750 
7562 7563 
IDM_MINFLOWLIM4 
W2
 
Minimum Flow 4 
Float
 
1000 
7564 7565 
IDM_MAXFLOWLIM0 
W2
 
Maximum Flow 0 
Float
 
500 
7566 7567 
IDM_MAXFLOWLIM1 
W2
 
Maximum Flow 1 
Float
 
1500 
7568 7569 
IDM_MAXFLOWLIM2 
W2
 
Maximum Flow 2 
Float
 
3000 
7570 7571 
IDM_MAXFLOWLIM3 
W2
 
Maximum Flow 3 
Float
 
4500 
7572 7573 
IDM_MAXFLOWLIM4 
W2
 
Maximum Flow 4 
Float
 
6000 
 
Table 21:  Flow Limiting Mode Table Parameters 
 
9.2  Real Time Parameters 
 
Real time parameters are status parameters that show the operation status of the 
XVG/eXVG.  Most of the real time parameters are read-only. 
 
Register 
Number 
XVG/eXVG Parameters 
Name 
Write 
Access 
Description Type 
3000 IDM_DIGDEMAND 
W0 
Valve Demand in Digital Command Mode, range 683-
3413 counts 
U16 
3001 IDM_DIGSTATUS 
RO 
Valve Feedback in Digital Command Mode, range 
683-3413 counts 
U16
 
3002 IDM_STATE 
RO 
Valve State: 0=Setup, 1=Run, 2=Shutdown, 
3=Calibration 
U16
 
3003 
IDM_SETUPVALID 
RO 
Setup Checksum Valid: 0=No, 1=Yes 
U16
 
3004 IDM_FLOWCOND 
RO 
Flow Condition: 0=Sonic, 1=Subsonic, 2=Reverse 
Flow 
U16
 
3005 IDM_SETUPCONNECT 
RO 
Setup Mode: 1=Set Valve in Setup State, 2=Exit Setup 
and Reset CPU 
U16
 
3006 
IDM_MEASFLOWCTS 
RO 
Measured Flow Counts, Range 0 – 4095  
U16
 
3007 
IDM_MEASFLOW3413 
RO 
Measured Flow Counts, Range 683 – 3413 
U16
 
3008 
IDM_RUNTMSECS 
RO 
Seconds elapsed since power on 
U16
 
3009 
IDM_RUNTMMINS 
RO 
Minutes elapsed since power on 
U16
 
3010 
IDM_SOLDUTYCYC 
RO 
Solenoid Duty Cycle, not used 
U16
 
3011 IDM_UPDATEPID 
RO Not 
used 
U16
 
3012 
IDM_ADCCALADC 
RO 
ADC A 0.22V ref calibration counts 0 – 4095  
U16
 
3013 
IDM_ADC3VOLTS3 
RO 
3.3V Supply counts, range 0 – 4095 
U16
 