 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 
 
Drive Time-Out Occurred on Physical Drive Bay X 
Description: ADU issued a command to a physical drive and the command was 
never acknowledged. 
Action: The drive or cable may be bad. Check the other error messages on the 
Diagnostics screen to determine resolution. 
 
Drive X Indicates Position Y 
Description: Message indicates a designated physical drive, which seems to be 
scrambled or in a drive bay other than the one for which it was originally 
configured. 
Action: Examine the graphical drive representation on ADU to determine proper 
drive locations. Remove drive and place it in drive position Y. Rearrange the 
drives according to the ADU instructions. 
 
Duplicate Write Memory Error 
Description: Data cannot be written to the array accelerator board in duplicate 
due to the detection of parity errors. This is not a data-loss situation. 
Action: Replace the array accelerator board. 
 
Error Occurred Reading RIS Copy from SCSI Port X Drive ID 
Description: An error occurred while ADU was trying to read the RIS from this 
drive. 
Action: HP stores the hard drive configuration information in the RIS. If multiple 
errors occur, the drive may need to be replaced. 
 
FYI: Drive (Bay) X is Third-Party Supplied 
Description: Third-party supplied the installed drive. 
Action: If problems exist with this drive, replace it with a supported drive.