 Troubleshooting 
169 
 
Identify Logical Drive Data did not Match with NVRAM 
Description: The identify unit data from the array controller does not match with 
the information stored in NVRAM. This can occur if new, previously configured 
drives have been placed in a system that has also been previously configured. 
Action: Run the server setup utility to configure the controller and NVRAM. 
 
Insufficient Adapter Resources 
Description: The adapter does not have sufficient resources to perform posted-
write operations to the array accelerator board. Drive rebuild may be occurring. 
Action: Operate the system without the array accelerator board until the drive 
rebuild completes. 
 
Inter-Controller Link Connection Could Not Be Established 
Description: Unable to communicate over the link connecting the redundant 
controllers. 
Action: Be sure both controllers are using the same hardware and firmware 
revisions. If one controller failed, replace it. 
 
Less Than 75% Batteries at Sufficient Voltage 
Description: The operation of the array accelerator board has been disabled due 
to less than 75% of the battery packs being at the sufficient voltage level. 
Action: Replace the array accelerator board if the batteries do not recharge 
within 36 powered-on hours.