MODEL 110 AUTORANGING DIGITAL MULTIMETER 
 
 
Accuracy specification:  ± ([…% of reading] + [… number of least 
significant digits]) at 18°C to 28°C (64°F to 
82°F) at less than 80% RH 
Temperature coefficient:  0.1
 x Specified Accuracy/°C 
Electromagnetic compatibility: 
 
Vac and Aac only: 
RF field = 3V/m 
 
Total accuracy: 
Specified accuracy + 2% of range 
Digital display: 
4000 counts 
 Sampling 
rate:  Twice per second 
Analog display: 
42 segments 
 Sampling 
rate:  20 times per second 
Overrange indication: 
Displays ‘OL’ when  value exceeds range 
selected 
Auto Power Off: 
30 minutes after last operation 
Power requirement: 
  Two 1.5V AAA batteries 
Battery life: 
  500 hours typical. Low battery indication. 
Safety: 
600V CAT II, Regulation EN61010: 
Part 1:1993 
Operating conditions: 
xOperating Temperature and Humidity:    0°C - 40°C (32°F - 104°F) 
 
Below 80% RH Non-condensing 
xStorage Temperature and Humidity:    -10°C - 60°C (14°F - 140°F) 
 
Below 70% RH Non-condensing 
xInstallation category II 
xPollution Degree 2 
xIndoor use only 
xAltitude up to 2000 meters (6500 feet) 
Dimensions: 
150
u72u35mm (5.9u2.8u1.4 in) 
Weight: 
Approx. 220g (7.8 oz) 
Accessories: 
Test Leads, Spare Fuse (0.5A/250V), 
Batteries, Instruction Manual 
 
 
MODEL 110 AUTORANGING DIGITAL MULTIMETER 
 
 
12 
7.0 Service and Maintenance 
7.1 Service 
and 
Repair 
Other than replacing the batteries and/or fuses, this instrument is 
NOT user serviceable. Consult qualified service and repair 
personnel for internal servicing. 
7.2 Maintenance 
Periodic maintenance is limited to cleaning of the external case 
with a damp cloth and mild detergent. Do not use harsh abrasives 
or solvents in cleaning this instrument.