installation directiVe
2
MAY 2006
S30 ENT M23 
13. CUSTOMIZED INSTRUMENT PANEL
Using only the components of the panel that are not wired 
to allow for panel customization, they will have to be wired 
using the 10 meter long wire harness, set up at one end for 
coupling to the JB connector and at the opposite end with 
conductors  with  free  terminals  with  identifying  numbering 
on each wire. The conductors will have to be connected to 
the individual components as indicated in the electrical and 
wiring diagrams in Chapter 22.
CAUTION
to assure the functionality of the safeties pertaining to the 
engine start/stop commands from the instrument panel or 
engine room, it is mandatory to wire the key switch strictly 
as shown in the electrical diagrams in chapter 22.
The  wiring  details  of  the  indications  and  alarms  module 
alone are provided below; indications for IVECO MOTORS 
indicator  instruments,  are  shown  in  the  related  wiring  dia-
grams in Chapter 22.
JD Connector for indications and alarms module
VIEW FROM THE INTEGRATED SIDE  
IN THE REAR PART OF THE MODULE
VIEW FROM THE TERMINAL SIDE  
OF THE COUPLING SIDE WIRING
Connector TRIDENT - ITT Cannon 
part # TST 24PA00
terminal 
female 
part # 192990-0050
lid 
rear 
part # TST24AH00
 
JD connects the indications and alarms module to the elec-
trical system of the engine (sensors, power supply, etc.).
The  terminal  part  of  the  wire  harness,  supplied  with  the 
module,  must  be  completed  using  female  terminals,  as 
described in the electrical diagram of Chapter 24.
For standard-equipped engines, to have the essential indica-
tions available, the following ways must be wired: 1, 2, 3, 7, 8, 
9, 10, 13, 14, 15, 17, 18, 19 with the female terminals supplied 
as standard equipment.