Справочник Пользователя для Iveco S30 ENT M23
installation directiVe
4
MAY 2006
S30 ENT M23
14. SENSORS FOR DETECTION AND PANEL SIGNALING
Coolant temperature sensor
Resistor with negative temperature coefficient, providing the
signal for analog temperature indication.
Operating voltage:
from 6V to 24 V
Calibration range
from 0 °C to 120 °C
Resistance value at 90 °C
51,2 ± 4,3 Ω
Electrical poles
isolated
High coolant temperature sensor
Switching coolant temperature sensor, providing the signal
for the related indicator.
Operating voltage:
from 6 to 24 V
Condition at ambient temperature
normally open
Closing temperature:
100 ± 3 °C
Electrical poles
isolated
Oil pressure sensor
Rheostat component providing the signal for the analog
indication of pressure.
Operating voltage
from 6V to 24 V
Calibration range
from 0 bar to 10 bar
Resistance value at 0 bar
10 Ω +3/-5 Ω
Resistance value at 2 bar
52 ± 4 Ω
Resistance value at 4 bar
88 ± 4 Ω
Resistance value at 6 bar
124 ± 5 Ω
Maximum value of resistance
184 Ω
Operating temperature
from - 25°C to 100°C
Electrical poles
isolated
Figure
Figure 40
Figure 41
04_027_C
04_237_N
04_236_N