Брошюра для White Rodgers 25M01A-100 25M Gas Dryer Valves

Скачать
Страница из 8
2
25M GAS CONTROL
PRODUCT INFORMATION
R-4080
general specifications
Standard Features
Natural Gas:
2.8" to 4.0" W.C.
3.5" to 5.4" W.C.
LP Gas:
8.5" to 11.4" W.C.
9.0" to 12.0" W.C.
Regulator Adjustment Range
Optional Features
25M
25M
Appliance
Manifold
X
X
Compact Size (3-13/32" x 2-1/2" - 2-19/32")
X
Split Coil
X
Single Solenoid
X
Dual Solenoid
X
X
Inlet Screen (protected from pipe damage)
X
X
Outlet Screen (protected from pipe damage)
X
X
Field Adjustable Regulator
X
X
Replaceable Operating coils without interrupting gas flow
X
X
Outlet Pressure Tap
X
Ambient Temperature Rating:  32˚ to 155˚F
X
Ambient Temperature Rating:  32˚ to 175˚F
X
X
Straight Through Outlet (offset)
X
.110 x .010 Male Terminals
X
3/16" Male Tab Type Terminals
25M
25M
Appliance
Manifold
X
Orifice Holder Outlet
X
X
Right/Left Angle Outlets
X
Dual Outlets (Right-Angle-Left AND Right-Angle-Right or Straight Through
X
Inverted Flare
X
British Threads (Rp)
X
Inlet Pressure Tap
X
Natural to LP Regulator Selector (convertible)
X
European Quiet-Type Solenoids
X
Encapsulated Leads
X
Ground Terminal
X
Tamper Evident Regulator Seal
X
Low Ambient Temperature Rating (-40˚ to 175˚F)
X
High Capacity Model (60 KBTU Natural Gas)
X
Two-Stage Operation (Right-Angle-Left or Right-Angle-Right Only)
Natural Gas:
5,000 to 55,000 BTU/hr
5,000 to 65,000 BTU/hr —
Dual Solenoid Independent
LP Gas:
8,000 to 89,000 BTU/hr
8,000 to 104,000 BTU/hr —
Dual Solenoid Independent
Range of Regulations
Part Number
From Natural Gas to Regulated LP:
F73-1493
Regulates between 9.0" to 12.0" W.C.
From LP to Natural Gas:
F73-1561
Regulates between 2.8" to 4.0" W.C.
From Natural gas to LP:
F69-2257
Blocks open the Regulator (Blocking Pin)
Conversion Kits