25M GAS CONTROL
PRODUCT INFORMATION
R-4080
general specifications
Current Requirements
12
24
24
24
120
120
240
240
DC
DC
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
.240
.120
.210
.175
.035
.030
.030
.025
.480
.240
.420
.350
.070
.060
.060
.050
Voltage
Frequency
Single Coil
Dual Coil, Parallel (total draw)
OPERATOR(S) REQUIREMENT (AMPS)
25M01A
25M01B
120
120
120
120
60
60
50
50
Start
Running
Start
Running
Glo-Bar On, Sensor Closed
Glo-Bar Off, Sensor Open
Glo-Bar On, Sensor Closed
Glo-Bar Off, Sensor Open
Model #
Rated Volts
Hertz
Operating Mode
Comments
SPLIT-COIL VERSIONS
1" P.D. Capacity
2" P.D. Capacity
Range of Regulation
Ambient Temperature 
Rating
Outlet Pressure 
Adjustment Range
40K
60K
5 to 55K
32˚ to 155˚ F
2.8" to 4.0"
25M01A
40K
60K
5 to 55K
32˚ to 175˚ F
2.8" to 4.0"
25M02
40K
60K
5 to 55K
-40˚ to 175˚ F
2.8" to 4.0"
25M12
48K
70K
5 to 65K
32˚ to 175˚ F
2.8" to 4.0"
25M04
48K
70K
5 to 65K
-40˚ to 175˚ F
2.8" to 4.0"
* 60K with both solenoids energized
+ 70K with both solenoids energized
25M14
30K/side*
35K/side+
5 to 65K
32˚ to 175˚ F
3.5" to 5.4"
30K/side*
35K/side+
5 to 65K
-40˚ to 175˚ F
3.5" to 5.4"
25M03
25M13
SPLIT-COIL
DUAL SOLENOID
REDUNDANT
DUAL SOLENOID
INDEPENDENT
SINGLE SOLENOID
52K
73K
25 to 85K
-40˚ to 175˚ F
2.8" to 4.0"
25M72
HIGH
CAPACITY
Maximum Pressure:  1/2 PSI
Agency Approvals:  CSA Int’l all models
Pipe Sizes
Inlet:
3/8" or 1/4" NPT or British Threads (Rp)
Straight In
Outlet:
3/8", 1/4", 1/8" NPT or British Threads (Rp)
or Orifice Holder
Right Angle Right (RAR), Right Angle Left (RAL), Offset Straight Through,
or Right Angle Right and Left (Dual Outlet)