Справочник Пользователя для Mitsubishi Electronics C64T

Скачать
Страница из 317
8.  Spindle Parameters 
8.3  MDS-B-SP/SPH, MDS-C1-SP/SPH 
232 
 
No. Items 
Details 
Setting 
range 
Standard 
setting 
3453 SP253 
 
DA1NO D/A 
output 
channel 1 
data 
number 
Set the output data number for channel 1 
of the D/A output function. 
When set to "0", the output is 
speedometer. 
Refer to "9.4 (1) For D/A output 
functions". 
–32768 to 
32767 
3454  SP254   DA2NO 
D/A output 
channel 2 
data 
number 
Set the output data number for channel 2 
of the D/A output function. 
When set to "0", the output is load meter. 
Refer to "9.4 (1) For D/A output 
functions". 
–32768 to 
32767 
3455  SP255   DA1MPY DA output 
channel 1 
magnifica- 
tion 
Set the data magnification for channel 1 
of the D/A output function. 
The output magnification is the setting 
value divided by 256. 
When set to "0", the output magnification 
becomes 1-fold, in the same manner as 
when "256" is set. 
Refer to "9.4 (1) For D/A output 
functions". 
–32768 to 
32767 
(1/256-fold) 
3456  SP256   DA2MPY DA output 
channel 2 
magnifica- 
tion 
Set the data magnification for channel 2 
of the D/A output function. 
The output magnification is the setting 
value  divided by 256. 
When set to "0", the output magnification 
becomes 1-fold, in the same manner as 
when "256" is set. 
Refer to "9.4 (1) For D/A output 
functions". 
–32768 to 
32767 