Справочник Пользователя для Mitsubishi Electronics C64T

Скачать
Страница из 317
8.  Spindle Parameters 
8.4  MDS-C1-SPM 
234 
8.4  MDS-C1-SPM 
 
The spindle parameter setting and display method will differ according to the NC being used, so refer to 
Instruction Manual for each NC and the following spindles. 
MELDAS AC Servo and Spindle MDS-C1 Series Specifications Manual  ........................BNP-C3000 
For parameters marked with a (PR) in the tables, turn the NC power OFF after setting. The parameters 
will be valid after the power is turned ON again.  
The "fixed control constants" and "fixed control bits" in this section are set by Mitsubishi.  
!
CAUTION 
!
  Do not make remarkable adjustments or changes of the parameters as the operation may 
become unstable. 
!
  In the explanation on bits, set all bits not used, including blank bits, to “0”. 
 
No. Items 
Details 
Setting 
range 
Standard 
setting 
3201 SP001 PGM  Magnetic sensor 
and motor built-in 
encoder 
orientation 
position loop gain 
As the set value is larger, the orientation 
time becomes shorter and servo rigidity is 
increased. 
However, vibration is increased and the 
machine becomes likely to overshoot. 
0 to 2000 
  (0.1 1/s) 
100 
3202 SP002 PGE  Encoder 
orientation 
position loop gain 
As the set value is larger, the orientation 
time becomes shorter and servo rigidity is 
increased. 
However, vibration is increased and the 
machine becomes likely to overshoot. 
0 to 2000 
  (0.1 1/s) 
100 
3203 SP003 PGC0 C-axis non-cutting 
position loop gain 
Set the position loop gain in C-axis 
non-cutting mode. 
During non-cutting (rapid traverse, etc.) 
with the C axis control, this position loop 
gain setting is valid. 
1 to 200 
  (1/s) 
15 
3204 SP004 OINP  Orientation 
in-position width 
Set the position error range in which an 
orientation completion signal is output.  
1 to 2880 
  (1/16  °) 
16 
3205 
(PR) 
SP005 OSP 
Orientation mode 
changing speed 
limit value 
Set the motor speed limit value to be used 
when the speed loop is changed to the 
position loop in orientation mode. 
When this parameter is set to "0", SP017 
(TSP) becomes the limit value. 
0 to 32767 
  (r/min) 
3206 SP006 CSP  Orientation mode 
deceleration rate 
As the set value is larger, the orientation 
time becomes shorter. However, the 
machine becomes likely to overshoot. 
1 to 1000 
20 
3207 SP007 OPST In-position shift 
amount for 
orientation 
Set the stop position for orientation. 
(i)  Motor built-in encoder, encoder: 
 
Set the value by dividing 360° by 
 4096. 
(ii) Magnetic sensor: 
 
Divide –5° to +5° by 1024 and put 
 
0° for 0. 
(i) 0 to 4095
(ii) –512  to 
512 
3208 
 
SP008 
 
Not used. Set to "0".