Справочник Пользователя для Mitsubishi Electronics C64T
6. Axis Specifications Parameters
6.3 Absolute Position Parameters
76
# Items
Details
Setting range (unit)
2054 clpush Current limit
(%)
Set up the current limit value for the initial setting when
detecting an absolute position with a dog-less system.
The setup value is the ratio of the current limit value to
the rated value.
detecting an absolute position with a dog-less system.
The setup value is the ratio of the current limit value to
the rated value.
0 to 100 (%)
2055 pushf
Push speed
Set the feedrate for the automatic initial setting during
stopper method.
stopper method.
1 to 999 (mm/min)
2056 aproch Approach
Set the approach distance for the automatic initial
setting in the stopper method.
Approach distance: After pushing onto the machine
setting in the stopper method.
Approach distance: After pushing onto the machine
stopper once‚ the tool returns this
distance‚ and then pushes again.
distance‚ and then pushes again.
When set to 0‚ the reference point coordinates set in
"#2037 G53ofs" will be used as the approach start
position.
"#2037 G53ofs" will be used as the approach start
position.
0 to 999.999 (mm)
2057 nrefp
Near zero
point +
point +
Set the width where the near-reference-point signal is
output. (Positive direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
output. (Positive direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
0 to 32.767 (mm)
2058 nrefn
Near zero
point
−
Set the width where the near-reference-point signal is
output. (Negative direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
output. (Negative direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
0 to 32.767 (mm)
2059 zerbas Select zero
point
parameter
and
reference
point
parameter
and
reference
point
Specify the position to be the zero point coordinate
during absolute position initial setting.
during absolute position initial setting.
0: Machine stopper position in machine stopper
method.
Marked point in marked point alignment method.
Marked point in marked point alignment method.
1: On the grid point just before machine stopper in
machine stopper.
On the grid point just before the marked point in
marked point alignment method.
On the grid point just before the marked point in
marked point alignment method.
0/1