Справочник Пользователя для Mitsubishi Electronics AD75P1/P2/P3

Скачать
Страница из 212
 
 
 
7 - 10                                                                                                                                                       7 - 10 
MELSOFT
7. SYSTEM CHECKING FROM PERIPHERAL DEVICE 
 
DISPLAY/SETTING DATA
 
 
Item Description 
Servo basic parameters 
Indicates the setting items of the servo basic parameters compared on the AD75M and 
peripheral device. 
For the setting items of the servo basic parameters, refer to Positioning module type 
A1SD75M1/M2/M3, AD75M1/M2/M3 User's Manual. 
Ax1 of AD75 
Indicates the servo basic parameters of axis #1 read from the servo amplifier to the AD75M. 
Ax1 of peripheral 
Indicates the servo basic parameters of axis #1 set to the project on the peripheral device. 
Ax2 of AD75 
Indicates the servo basic parameters of axis #2 read from the servo amplifier to the AD75M. 
Ax2 of peripheral 
Indicates the servo basic parameters of axis #2 set to the project on the peripheral device. 
Ax3 of AD75 
Indicates the servo basic parameters of axis #3 read from the servo amplifier to the AD75M. 
Ax3 of peripheral 
Indicates the servo basic parameters of axis #3 set to the project on the peripheral device. 
"Reload" button 
When executing the servo starting up function, click this button to read the servo basic 
parameters again from the servo amplifiers. 
"Servo end"/"Online" 
button 
Click the "Servo end" button to end the AD75M test mode and terminate the model name 
check. 
Click the "Online" button to place the AD75M in the test mode and enable reread.