7. SYSTEM CHECKING FROM PERIPHERAL DEVICE 
 
7.3.3 Servo upper/lower limit check 
PURPOSE
 
 
Perform forward or reverse JOG operation to make sure that the upper and lower 
limit switches installed in the positioning system operate properly. 
 
BASIC OPERATION
 
 
1. Choose AD75M Servo starting up. 
Double-click.
Double-click.
 
2. Click the "OK" button in the AD75M test mode shift confirmation dialog box. 
3. Click the <<U/L limit check>> tab on the AD75M servo starting up main screen. 
4. Make sure that the signals are in the following states. 
Servo, Ready, Upper limit, Lower limit: z (ON) 
Alarm, Stop: { (OFF) 
5. Set the JOG speed. 
6. Choose the arrow ( 
 
 ) of the JOG operation direction. 
7. Move the mouse pointer (   ) to the chosen arrow and press the left button of 
the mouse or press the space key on the keyboard to start JOG operation. 
Hold down the mouse's left button or the space key to execute JOG operation. 
8. Perform JOG operation to move the axis into contact with the upper/lower limit 
switch, and make sure that "OK" appears at Upper or Lower limit. 
9. To exit, click the "Servo end" button and click the "OK" button in the test mode 
end confirmation dialog box.