Справочник Пользователя для Mitsubishi Electronics AD75P1/P2/P3

Скачать
Страница из 212
 
 
 
7 - 12                                                                                                                                                       7 - 12 
MELSOFT
7. SYSTEM CHECKING FROM PERIPHERAL DEVICE 
 
DISPLAY/SETTING SCREEN
 
 
 
 
DISPLAY/SETTING DATA
 
 
Item Description 
Servo status 
External I/O 
Indicates the states of the signals from external devices connected to the AD75M. 
JOG speed 
Set the speed for JOG operation. 
JOG operation 
Choose the arrow ( 
 
 ) of the axis for JOG operation and press the mouse's left 
button or the space key to start JOG operation. 
The arrow is red during operation. 
Upper limit 
Lower limit 
"OK" appears when the upper or lower limit signal turns off during JOG operation. 
JOG speed limit 
Acc 
Dec 
Indicates the JOG speed limit values, JOG speed accel times and JOG speed decel times 
set to extended parameters 2 (refer to Section 8.1.4). 
Upper stroke limit 
Lower stroke limit 
Indicates the software stroke upper and lower limits set to extended parameters 1 (refer to 
Section 8.1.3). 
Address 
Speed 
Error 
Warning 
Indicates the feed addresses, axis speeds, error codes and warning codes of the axes. 
"Data clear" button 
When rechecking the upper or lower limit, click this button to clear the result. 
"Servo end"/"Online" 
button 
Click the "Servo end" button to end the AD75M test mode and terminate the upper/lower limit 
check. 
Click the "Online" button to place the AD75M in the test mode and start the upper/lower limit 
check.