7. SYSTEM CHECKING FROM PERIPHERAL DEVICE 
 
7.3.4 Servo speed check 
PURPOSE
 
 
Perform forward/reverse JOG operation to make sure that the servomotor speed 
does not exceed the motor speed set in the servo parameter. 
 
BASIC OPERATION
 
 
1. Choose AD75M Servo starting up. 
Double-click.
Double-click.
 
2. Click the "OK" button in the AD75M test mode shift confirmation dialog box. 
3. Click the <<RPM check>> tab on the AD75M servo starting up main screen. 
4. Make sure that the signals are in the following states. 
Servo, Ready, Upper limit, Lower limit: z (ON) 
Alarm, Stop: { (OFF) 
5. Set the JOG speed. 
6. Choose the arrow ( 
 :Forward  
 :Reverse ) of the JOG operation 
direction. 
7. Move the mouse pointer (   ) to the chosen arrow and press the left button of 
the mouse or press the space key on the keyboard to start JOG operation. 
Hold down the mouse's left button or the space key to execute JOG operation. 
8. Perform JOG operation, and check that the Max. For. and Max. Rev. speeds 
are not more than their parameter settings. 
9. To exit, click the "Servo end" button and click the "OK" button in the test mode 
end confirmation dialog box.