445
(2) SF-THY
Motor type
SF-THY
Applicable inverter 
FR-A720-……K
FR-A740-……K
90
90
110
132
160
185
220
280
Rated output (kW)
75
75
90
110
132
160
200
250
Rated torque (kgf
·
m)
(N
·
m)
48.7
477
48.7
477
58.4
572
71.4
700
85.7
840
103.9
1018
129.9
1273
162.3
1591
Maximum torque(kgf
·
m)
150%60s
(N
·
m)
73.0
715
73.0
715
87.6
858
107.1
1050
128.5
1260
155.8
1527
194.8
1909
243.4
2386
Rated speed (r/min)
1500
1500
Maximum speed (r/min)
2400
2400
1800
Frame No.
250MD
250MD
250MD
280MD
280MD
280MD
280L
315H
Inertia moment J (kg
·
m
2
)
1.1
1.1
1.7
2.3
2.3
4.0
3.8
5.0
Noise
90dB
90dB
95dB
Cooling 
fan
Voltage
Three-phase, 200V/50Hz, 200V/60Hz, 220V/60Hz
(400V class cooling fan is available upon order)
Input (W)
50Hz
750
400
400
400
400
400
750
750
60Hz
750
750
750
750
750
1500
1500
Approx. mass (kg)
610
610
660
870
890
920
1170
1630
Co
m
m
on spe
cif
ic
at
io
ns
Surrounding air 
temperature, humidity
-10 to +40°C (non-freezing), 90%RH or less (non-condensing)
Structure 
Totally enclosed forced draft system 
Detector
Encoder 2048P/R, A phase, B phase, Z phase +12VDC power supply 
*1
Equipment
Encoder, thermal protector
*2
, fan
Insulation
Class F
Vibration rank
V10
Dedica
te
d enc
ode
r Resolution
2048 pulse/rev
Power supply voltage
12VDC±10%
Current 
consumption
90mA
Output signal form
A, B phases (90° phase shift) Z phase: 1 pulse/rev
Output circuit
Complementary (constant voltage output matched by emitter follow)
Output voltage
"H" level: Power supply voltage 9V or more (I
OH
: -20mA)
"L" level: Power supply voltage 3V or less (I
OL
: 20mA)
*1
The 12V power supply or the control terminal option (FR-A7PS) is required as the power supply for the encoder.
*2
A motor with a thermal protector is also available. Contact your sales representative.