Справочник Пользователя для Daewoo KOR-631H0P

Скачать
Страница из 36
MEASUREMENT AND TEST
1. MEASUREMENT OF THE MICROWAVE POWER OUTPUT 
M icrowave output power can be checked by indirectly m easuring the tem perature rise of a certain am ount of water exposed 
to the m icrowave as directed  below.
PROCEDURE
1. M icrowave power  output  m easurem ent is m ade with  the  m icrowave oven supplied  at rated voltage and  operated at  its 
m axim um  m icrowave power setting  with a load of  1000  ±  5cc  of potable  water.
2. The water is contained in a cylindrical borosilicate glass vessel having a m axim um  m aterial thickness of 3 m m  and an
outside diam eter of  approxim ately 190  m m .
3. The oven and  the em pty  vessel are at  am bient  tem perature prior  to the start of  the test.  The initial  tem perature of the
water  is 10 ±  2 ° C  (50 ±  3.6  ° F).  It  is m easured im m ediately before the  water is added to  the vessel. After  addition of 
the water to the  vessel, the load is im m ediately placed on the center of the shelf, which is in  the lowest  norm al position.
4. M icrowave power  is switched on.
5. Heating tim e should be exactly A  seconds.
(Refer to table as  following)
Heating tim e is m easured while  the
m icrowave generator is operating at
full power.  The filam ent heat-up  tim e 
for m agnetron is not included.
6. The initial and final  tem perature of water is selected 
so that  the  m axim um   difference between the  am bient 
and final water tem perature is 5K.
7. The m icrowave  power output P  in watts is  calculated 
from  the following form ula:
 
T is difference between initial and ending tem perature.
t is the heating tim e.
The  power  m easured  should be  B (Refer to   SPECIFICATIO NS)  W  ±  10.0 % .
Heating time for power output:
A  (second)
70
64
60
56
52
49
47
44
42
40
38
B  (W )
600
650
700
750
800
850
900
950
1000
1050
1100
P  = 4187 X 
T
CAUTION
1. W ater load should be m easured exactly to 1 liters.
2. Input pow er voltage should be exactly specified voltage (R efer to S PE C IF IC AT IO N S ).
3. A m bient tem perature should be 20 
±  2° C (68  ±  3.6 ° F)