MEASUREMENT AND TEST
3. COMPONENT TEST PROCEDURE
High voltage  is  present  at the high voltage  term inal of the high voltage  transform er during any cooking  cycle.
It is neither  necessary nor advisable to attem pt m easurem ent of  the high voltage.
 Before touching any oven components or wiring, always unplug the oven from its power source and discharge the capacitor.
1. High voltage transformer
1)  Rem ove  connections from  the transform er term inals  and check continuity.
2)  Norm al readings should  be as follows :
Secondary winding  ... Approx. 100 
± 10%
Filam ent  winding ...  Approx.  0 
Prim ary winding  ... Approx. 1 
2. High voltage capacitor
1)  Check  continuity of capacitor  with   m eter on the highest  O HM  scale.
2) A norm al capacitor will show continuity for a short tim e, and then indicate  10M
once the capacitor charged.
3) A shorted capacitor will show continuous continuity.
4) An open capacitor will show constant 10M
.
5)  Resistance between  each  term inal  and chassis should be infinite.
3. High voltage diode
1)  Isolate  the diode  from  the  circuit by disconnecting the  leads.
2) W ith the ohm m eter set on the highest resistance scale m easure the resistance across the diode term inals. Reverse
the  m eter leads and  again observe the resistance reading.  M eter with  6V,  9V  or higher voltage  batteries should be
used to check the front-back resistance of the diode, otherwise an infinite resistance m ay be read in both directions. A
norm al diode's resistance  will  be infinite  in one direction  and several  hundred k 
 in the  other  direction.
4. Magnetron
For com plete m agnetron diagnosis, refer to “M easurem ent of the M icrowave Power O utput. " Continuity checks can only 
indicate and open  filam ent  or a shorted m agnetron. To  diagnose for an open filam ent or  a  shorted m agnetron, 
1)  Isolate  m agnetron from  the circuit by disconnecting the leads.
2) A continuity check across m agnetron filam ent term inals should indicate 0.1 
 or less.
3) A continuity check between each filam ent term inal and m agnetron case should read open.
5. Fuse
If the fuse in  the  prim ary and m onitor  switch  circuit is blown when  the door  is opened, check the prim ary  and m onitor
switch before replacing the  blown fuse. In  case  the fuse  is  blown by an im proper switch operation, replace  the  defective