MEASUREMENT AND TEST
2. MICROWAVE RADIATION TEST
PROCEDURE
1. Prepare M icrowave Energy Survey M eter, 
600cc glass  beaker, and  glass therm om eter 
100° C (212° F ).
2.  Pour  275cc  ± 15cc  of tap water  initially at 20 ±   5  ° C 
(68  ±  9° F) in  the 600 cc glass beaker  with an inside
diam eter of approx. 95 m m (3.5 in.).
3.  Place it at  the center of the  tray and  set  it  in a cavity.
4.  Close the door and operate  the oven.
5.  M easure the leakage by using M icrowave  Energy
Survey  M eter with dual  ranges,  set  to 2450M Hz.
1)  M easured radiation leakage m ust not  exceed the
value prescribed below. Leakage for a fully assem bled 
oven with door norm ally closed m ust be less than 4m W /cm
2
.
2)  W hen m easuring the leakage, always use the 5 cm   (2 in.) space cone with probe. Hold the probe perpendicular to the 
cabinet and door. Place the space cone of the probe on the door, cabinet, door seem , door viewing screen, the exhaust
air  vents and  the  suction air vents.
3)  M easuring should be in  a  counter-clockwise direction  at a rate  of 1 in./sec.  If  the leakage of the  cabinet door seem   is
unknown,  m ove the probe m ore slowly.
4)  W hen  m easuring near a corner of the  door, keep the probe perpendicular to  the areas m aking sure the probe  end at
the base of  the cone does not get  closer than 2 in. from  any  m etal. If  it  does  not, erroneous reading m ay result.
CAUTION
1. M ake  sure  to check  the m icrowave leakage before and after repair  of adjustm ent.
2. Always  start  m easuring of  an unknown field  to assure safety for operating personnel from  m icrowave energy.
3. Do not  place your hands into any  suspected m icrowave  radiation field  unless  the safe  density level is  known.
4. Care  should  be  taken not to  place the eyes  in direct line  with the  source of m icrowave  energy.
5. Slowly approach the unit  under test until  the  radiom eter reads an  appreciable  m icrowave leakage from  the unit 
under  the test.