Справочник ПользователяСодержаниеAXP1406/AXP1600 Subsystem IPMI1Contents3List of Tables7About this Manual11Overview of Contents11Abbreviations12Conventions12Summary of Changes13Comments and Suggestions14Supported IPMI Commands151.1 Introduction151.2 Standard IPMI Commands151.2.1 Global IPMI Commands151.2.2 BMC WatchDog Timer Commands161.2.3 BMC Device and Messaging Commands161.2.4 Chassis Device Commands171.2.5 Event Commands171.2.6 PEF and Alerting Commands171.2.7 Sensor Device Commands181.2.8 FRU Device Commands191.2.9 SDR Device Commands191.2.10 SEL Device Commands191.2.11 LAN Device Commands201.2.12 Serial/Modem Device Commands201.3 PICMG 3.0 Commands211.4 Emerson and Pigeon Point OEM Commands22FRU Information and Sensor Data Records252.1 Introduction252.2 Total Power Consumption252.3 SAM1000 Physical Shelf Manager262.3.1 SAM Physical FRU Information262.3.1.1 Physical Shelf Manager FRU Data, AXP1406262.3.1.2 Physical Shelf Manager FRU Data, AXP1600272.3.2 E-Keying282.3.3 Power Configuration282.3.4 Sensor Overview292.3.5 SAM Physical Shelf Manager Analog Sensors302.3.5.1 Voltage Sensors302.3.5.2 Temperature Sensors322.3.6 SAM Module Discrete Sensors342.3.6.1 Hot Swap Sensor352.3.6.2 IPMB Link Sensor352.3.6.3 PEM A Sensor362.3.6.4 PEM B Sensor372.3.6.5 AXP Backplane ID Sensor392.3.6.6 +12 V B Valid Sensor392.3.6.7 +12 V A Valid Sensor402.3.6.8 Fault Event Sensor412.3.6.9 POST Results Sensor412.3.6.10 Shelf FRU Info Sensor422.3.6.11 CPLD State Sensor432.4 SAM1000 Active (Virtual) Shelf Manager432.4.1 FRU Information432.4.1.1 Active Shelf Manager FRU Data, AXP1406442.4.1.2 Active Shelf Manager FRU Data, AXP1600462.4.1.3 SAM1000 Shelf Manager FRU Data482.4.1.4 Fan Tray FRU Data, AXP1406492.4.1.5 Fan Tray FRUs 1,2, and 3 Data502.4.1.6 Fan Tray FRUs 4, 5, and 6 Data512.4.1.7 Fan Tray FRUs 7 and 8 Data512.4.1.8 Fan Tray FRU Data, AXP1600522.4.1.9 Fan Tray FRUs 1, 2, and 3 Data, AXP1600532.4.1.10 Fan Tray FRUs 4, 5, and 6 Data, AXP1600542.4.1.11 Fan Tray FRUs 7, 8 and 9 Data, AXP1600552.4.2 E-Keying552.4.3 Power Configuration562.4.4 Active SAM1000 Sensor Overview562.4.5 Active SAM1000 Analog Sensors612.4.5.1 Fan Speed Sensors612.4.5.2 Fan Voltage Sensors702.4.6 SAM Active Shelf Manager Discrete Sensors922.4.6.1 Hot Swap Sensors932.4.6.2 Shm Fault Event Sensor982.4.6.3 IPMB Link Sensor992.4.6.4 Telco Alarm Sensor1122.4.6.5 BMC Watchdog Sensor1132.4.6.6 System Event1132.4.6.7 Fan Tray Presence Sensor1142.4.6.8 Fan Tray -48 V Fuse Sensor1192.5 Power Entry Module Sensor Data Records1242.5.1 PEM FRU Information1242.5.2 E-Keying1252.5.3 Power Configuration1252.5.4 Power Entry Module Sensor Overview1262.5.5 Power Entry Module Analog Sensors1262.5.5.1 Voltage Sensors1272.5.5.2 Current Sensor1312.5.5.3 Temperature Sensor1322.5.6 Power Entry Module Discrete Sensors1322.5.6.1 Hot Swap Sensor1322.5.6.2 IPMB Link Sensor1332.5.7 Circuit Breaker State Sensors134OEM Sensors1373.1 OEM Sensors1373.1.1 Telco Alarms (Pigeon Point OEM)1373.1.2 AXP Backplane ID (Emerson OEM)1383.1.3 POST Results (Emerson OEM)1383.1.4 Shelf FRU Info (Emerson OEM)1393.1.5 FT -48 V Fuse (Emerson OEM)1393.1.6 Shm Fault Event (Emerson OEM)140A System Behavior in Response to Sensor Events141A.1 Introduction141A.2 Cooling Management in Normal Operation Mode141A.3 Cooling Management in Abnormal Operation Mode141A.4 Adaptive Adjustment of the Minimum Fan Level142A.5 FRU State Management144B Related Documentation147B.1 Emerson Network Power - Embedded Computing Documents147B.2 Manufacturers’ Documents148B.3 Related Specifications148Размер: 3,5 МБСтраницы: 148Язык: EnglishПросмотреть