Справочник ПользователяСодержаниеSAFETY PRECAUTIONS3CONDITIONS OF USE FOR THE PRODUCT9REVISIONS10INTRODUCTION11CONTENTS11COMPLIANCE WITH EMC AND LOW VOLTAGE DIRECTIVES15GENERIC TERMS, ABBREVIATIONS, AND TERMS16PACKING LIST17CHAPTER1 OVERVIEW181.1 Features19CHAPTER2 SYSTEM CONFIGURATION212.1 Applicable Systems212.2 When Using the Q68RD3-G with Redundant CPU252.3 How to Check the Function Version, Serial No., and Software Version26CHAPTER3 SPECIFICATIONS293.1 Performance Specifications293.2 Function List313.2.1 Temperature conversion system323.2.2 Conversion setting for disconnection detection function373.2.3 Warning output function393.3 I/O Signals for Communicating with Programmable Controller CPU453.3.1 I/O signal list453.3.2 I/O signal details463.4 Buffer Memory523.4.1 Buffer memory assignment523.4.2 Conversion enable/disable setting (Un\G0)583.4.3 CH[] Time/Count/Moving average/Time constant setting (Un\G1 to Un\G8)593.4.4 Conversion completion flag (Un\G10)603.4.5 CH[] Measured temperature value (Un\G11 to Un\G18)613.4.6 Error code (Un\G19)623.4.7 Setting range 1, 2 (Un\G20 and Un\G21)623.4.8 Setting range 3 (Offset/gain setting) (Un\G22)623.4.9 Averaging processing selection (Un\G24 and Un\G25)633.4.10 Offset/gain setting mode (Un\G26 and Un\G27)643.4.11 CH[] Offset/gain temperature setting values (Un\G28 to Un\G43)653.4.12 Warning output enable/disable setting (Un\G46)653.4.13 Warning output flag (Process alarm/Rate alarm) (Un\G47 and Un\G48)663.4.14 Disconnection detection flag (Un\G49)673.4.15 CH[] Scaling value (Un\G50 to Un\G57)693.4.16 Scaling valid/invalid setting (Un\G58)703.4.17 CH[] Scaling range upper/lower limit values (Un\G62 to Un\G77)713.4.18 CH[] Scaling width upper/lower limit values (Un\G78 to Un\G93)713.4.19 CH[] Process alarm upper/lower limit values (Un\G94 to Un\G125)723.4.20 CH[] Rate alarm warning detection period (Un\G126 to Un\G133)733.4.21 CH[] Rate alarm upper/lower limit values (Un\G134 to Un\G149)733.4.22 Mode switching setting (Un\G158 and Un\G159)743.4.23 Conversion setting for disconnection detection (Un\G164 and Un\G165)753.4.24 CH[] Conversion setting value for disconnection detection (Un\G166 to Un\G173)763.4.25 Factory default offset/gain values, User range settings offset/gain values, User range settings resistance offset/gain values (Un\G190 to Un\G253)77CHAPTER4 PROCEDURES AND SETTINGS BEFORE SYSTEM OPERATION784.1 Handling Precautions784.1.1 Fixing module with module fixing bracket794.2 Procedures and Settings before System Operation804.3 Part Names814.4 Wiring834.4.1 Wiring precautions834.4.2 External wiring844.5 Intelligent Function Module Switch Setting854.6 Offset/Gain Setting87CHAPTER5 UTILITY PACKAGE (GX Configurator-TI)935.1 Utility Package Functions935.2 Installing and Uninstalling Utility Package955.2.1 Precautions for use955.2.2 Operating environment985.3 Operating Utility Package1005.3.1 Common operations1005.3.2 Operation overview1035.3.3 Activating intelligent function module utility1055.4 Initial Setting1075.5 Auto Refresh Setting1095.6 Monitor/Test1115.6.1 Monitor/test screen1115.6.2 Offset/gain setting operation1145.6.3 OMC (Online Module Change) refresh data117CHAPTER6 PROGRAMMING1186.1 Programming Procedure1196.2 Using Programs in Normal System Configuration1216.2.1 Before creating a program1236.2.2 Program example when utility package is used1256.2.3 Program example when utility package is not used1306.3 Using Programs on Remote I/O Network1356.3.1 Before creating a program1376.3.2 Program example when utility package is used1386.3.3 Program example when utility package is not used142CHAPTER7 ONLINE MODULE CHANGE1497.1 Conditions Required for Online Module Change1507.2 Operations during Online Module Change1517.3 Procedures of Online Module Change1527.3.1 When factory default is used and initial setting has been made with GX Configurator-TI1527.3.2 When factory default is used and initial setting has been made with sequence program1577.3.3 When user range setting is used and initial setting has been made with GX Configurator-TI (Separate system is available)1617.3.4 When user range setting is used and initial setting has been made with GX Configurator-TI (Separate system is not available)1667.3.5 When user range setting is used and initial setting has been made with sequence program (Separate system is available)1727.3.6 When user range setting is used and initial setting has been made with sequence program (Separate system is not available)1777.4 Range Reference Table1827.5 Precautions for Online Module Change185CHAPTER8 TROUBLESHOOTING1868.1 Error Code List1868.2 Troubleshooting1888.2.1 When "RUN" LED turns off1888.2.2 When "RUN" LED flashes1888.2.3 When "ERR" LED flashes1888.2.4 When "ERR" LED turns on1888.2.5 When "ALM" LED flashes1898.2.6 When "ALM" LED turns on1898.2.7 When Disconnection detection signal (XC) turns ON1898.2.8 When measured temperature value cannot be read1898.2.9 When measured temperature value is abnormal1908.2.10 Checking Q68RD3-G status using system monitor of GX Developer191APPENDICES193Appendix 1 Dedicated Instructions193Appendix 1.1 List of Dedicated Instructions and Available Devices193Appendix 1.2 G(P).OFFGAN194Appendix 1.3 G(P).OGLOAD196Appendix 1.4 G(P).OGSTOR200Appendix 2 External Dimensions205INDEX207WARRANTY209Размер: 4,2 МБСтраницы: 212Язык: EnglishПросмотреть