Roland AR-200 用户手册

下载
页码 72
 
35
Controlling the AR-200 from an External Device (Control Input Connectors)
 
Applications
 
Connecting Equipment
 
Connectors Used in Terminal Rec
 
1–8: Phrases are specified in binary format using 
combinations of 0 (Off) and 1 (On).
9, 10: Combinations of 0 (Off) and 1 (On) are used to specify 
record, erase, and playback.
15–18 (CONT OUT): Outputs signals for confirming the 
presence or absence of phrases.
In addition to the connectors just described, shorting Ports 11 
and 12 (Ground) enables “On.”
 
fig.inp-23
 
 
 
Operational Specifications for 
Terminal Rec
 
Phrases are specified by combinations of signals of 0 (Off) 
and 1 (On) to the Port Nos. 1 through 8 as well as Port Nos. 
11 and 12, and record, playback, and erase functions are 
specified with combinations of control signals of 0 (Off) and 
1 (On) to Port Nos. 9 and 10.
 
Presence or Absence of Phrases
 
If there is a binary-specified phrase that has already been 
recorded, a signal is output from the CONT OUT connector 
(Port No. 15). If there is an empty phrase, no signal is output.
 
* During Terminal Rec, the CONT OUT connector functions as 
a connector for signals confirming the presence or absence of 
phrases. Note that this differs from the normal function of 
CONT OUT.
 
fig.inp-24
 
Recording
 
9: 0 (Off)
10: 1 (On)
 
 → 
 
While control signals are being input, the specified phrase
is recorded. When input of the control signal stops, 
recording then ends.
 
fig.inp-25
 
* Recording does not start if there is a binary-specified phrase 
that has already been recorded (the recording instruction is 
disabled). When recording, either specify an empty phrase or 
delete the existing phrase before recording the new one. 
Additionally, in Terminal Rec, since a make signal is output 
from the CONT OUT connector when a specified phrase has 
already been recorded, this allows confirmation using a 
connected external control device.
* When headphones are being used, no Busy Out signal is 
output.
* When you're using the Terminal Recording Mode, recording 
takes place immediately, without entering trigger recording 
standby. 
10
1
18
15
8
Select a Phrase
9
Rec /Play /Delete
CONT OUT
12 11
GND
Tbcd
-
250
min
max
(msec)
(the presence or absence
of phrases)
Binary Specification
Port No.1--8
Tbcd
Timing Chart (The presence or absence of phrases)
Binary Phrase Output Delay Times
:
Control Out
Timing Chart (Rec)
Trw
Tbrs
Tbrh
Tbrd
Tvrd
Tbred
Tvred
300
200
100
-
-
-
-
-
-
-
300
300
100
100
min
max
(msec)
AUDIO OUTPUT
Busy Out
Port No.10
Tvred
Trw
Tbrs
Tbrh
Tbrd
Tvrd
Tbred
Binary Specification
Port No.1--8
: Play Pulse Width
: Binary Setup Time
: Binary Hold Time
: Busy Delay Time
: Audio Delay Time
: End Busy Delay Time
: End Audio Delay Time
AR-200_e.book 35 ページ 2003年7月14日 月曜日 午後1時11分