Roland AR-200 用户手册

下载
页码 72
 
36
Controlling the AR-200 from an External Device (Control Input Connectors)
 
Playback
 
9: 1 (On)
10: 0 (Off)
 
 →
 
 The specified phrase is played back. Even when control 
signals are input continuously, the phrase is played back
one time only and then ends.
 
fig.inp-26
 
* Playback does not begin if the binary-specified phrase is empty 
(the playback instruction is disabled). When playing back, 
specify a phrase that has already been recorded.
* When headphones are being used, no Busy Out signal is 
output.
 
Erase
 
9: 1 (On)
10: 1 (On)
 
    →
 
 First, when ON is input to Port No. 9, and then ON is
input to Port No. 10, erasure of the specified phrase
begins. Erasure ends when the signal from the CONT-
OUT connector confirming the presence or absence of
the phrase changes to OFF.
 
* Erasure does not begin if the binary-specified phrase is empty 
(the erase instruction is disabled). When erasing, specify a 
phrase that has already been recorded.
 
fig.inp-27
 
AR-200 Settings
 
Switching the Terminal Recording 
Mode
 
Set the MODE switches on the AR-200’s bottom panel to 
select the Terminal Rec (BINARY REC) mode.
You cannot achieve control input playback merely by 
connecting a device to the port. Be sure to set the control 
input mode and match the method used for connecting to the 
connectors.
 
Procedure for Setting the Control Input Mode
 
1.
 
Turn off the power of the AR-200.
 
2.
 
Set the MODE switches on the AR-200’s bottom panel as 
shown below.
SW6: ON
 
3.
 
Turn on the power of the AR-200.
 
* Use a pointed object to change the ON/OFF settings of the 
MODE switches.
Timing Chart (PLAY)
Tpw
Tbps
Tbph
Tbpd
Tvpd
Tvbd
(msec)
20
200
100
-
-
-
-
-
-
300
300
100
min
max
Tvbd
Tpw
Tbps
Tbph
Tbpd
Tvpd
AUDIO OUTPUT
Busy Out
Port No.9
Binary Specification
Port No.1--8
: Play Pulse Width
: Binary Setup Time
: Binary Hold Time
: Busy Delay Time
: Audio Delay Time
: End Busy Delay Time
Timing Chart ( Delete)
Trdw
Tpds
Tpdh
Tprd
Tbds
Tbdh
Tbcd
Tpdd
100
50
50
0
200
20
-
-
-
-
-
-
-
-
250
*2500(typ.)
min
max
(msec)
Tpdd
Trdw
Tpds
Tpdh
Tprd
Tbds
Tbdh
Tbcd
Port No.10
Binary Specification
Port No.1--8
Port No.9
(the presence or absence
of phrases)
Control Out
: Delete Rec Pulse Width
: Delete Play Setup Time
: Delete Play Hold Time
: Delete Play Rec Delay Time
: Delete Binary Setup Time
: Delete Binary Hold Time
: Binary Phrase Output Delay Time
: Play Phrase Output Delay Time
*Play phrase output delay time is dependent on the card used. 
AR-200_e.book 36 ページ 2003年7月14日 月曜日 午後1時11分