Procom ML150HPA 用户手册

下载
页码 25
10
Figure 15 -Equipment  Shutoff  Valve
INSTALLATION
CHECKING GAS
CONNECTIONS
            
WARNING:    Test  all  gas
piping   and  connections  for  leaks
after installing or servicing. Correct
all  leaks at  once.
          
 WARNING:   Never  use  an
open    flame    to    check    for   a
leak.  Apply   a   mixture   of   liquid
soap   and   water      to   all   joints.
Bubbles   forming    show  a  leak.
Correct  all   leaks at  once.
Pressure  Testing  Gas  Supply
Piping  System
Test  Pressures  In  Excess  Of
1/2  PSIG  (3.5 K Pa)
1.   Disconnect   appliance   with   its
       appliance       main        gas     valve
     (control valve)   and   equipment
      shutoff    valve   from   gas   supply
         piping    system.   Pressures   in
       excess  of   1/2  psig  will  damage
      heater  regulator.
2.    Cap   off  open   end   of   gas  pipe
where  equipment  shutoff  valve
       was   connected.
3.     Pressurize             supply           piping
s ys t e m     b y    e i t h e r   u s i n g
compressed   air   or    opening
       propane/LP  supply  tank  valve.
4.   Check  all  joints  of  gas  supply
piping  system.  Apply  mixture  of
liquid  soap  and  water  to  gas
joints.  Bubbles    forming    show
      a  leak.
5.   Correct  all  leaks  at  once.
6.   Reconnect heater and equipment
       shutoff  valve  to  gas supply.  Check
reconnected   fittings  for  leaks.
Test  Pressures  Equal  To or
Less  Than  1/2  PSIG  (3.5 K Pa)
1.   Close equipment  shutoff  valve
       (see Figure 15).
2.   Pressurize  supply  piping  system
       by  either  using  compressed  air
      or  opening  propane/LP  supply
      tank  valve.
3.   Check  all  joints  from  propane/LP
        supply  tank  to  equipment  shutoff
     valve  (see   Figure 16).  Apply
      mixture  of  liquid  soap and water
       to  gas joints.  Bubbles  forming
       show  a  leak.
4.   Correct  all  leaks  at  once.
Pressure  Testing  Heater  Gas
Connections
1.  Open  equipment  shutoff  valve
      (see  Figure  15).
2.   Open propane/LP  supply  tank
      valve.
3.   Make    sure    control    knob    of
      heater  is  in  the  OFF position.
4.   Check  all  joints  from  equipment
      shutoff   valve   to   control   valve
      (see Figure 16 ).  Apply  mixture  of
        liquid   soap    and    water  to   gas
       joints. Bubbles  forming   show
      a  leak.
5.   Correct all leaks at once.
6.   Light    heater    (see   Operating
Heater,  pages  10  and  11  for
      non-thermostat      models      or
page 12  and  13   for  thermostat
models).  Check   the  rest  of  the
       internal  joints  for  leaks.
7.   Turn  off  heater (see  To  Turn  Off
Gas  to  Appliance,  page 11  for
non-thermostat  models  or  page
       12  for thermostat  models).
8.    Replace  lower  front  panel.
NON-THERMOSTAT  MODELS
n
FOR YOUR SAFETY
n
READ BEFORE LIGHTING
            WARNING:   If  you  do  not
follow  these   instructions  exactly,
a   fire  or   explosion  may   result
in   causing  property damage,
personal injury  or  loss of life.
A.  When  lighting  the  pilot,  follow
      these  instructions  exactly.
B.  BEFORE  LIGHTING   smell  all
     around   the  appliance  area  for
     gas.  Be  sure  to  smell  next  to
      the  floor  because  some  gas  is
     heavier  than  air  and  will  settle
      on the  floor .
WHAT TO DO  IF YOU SMELL GAS
Do  not  try  to  light any  appliance.
Do not touch any electric switch;
        do  not  use  any  phone  in  your
       building.
Immediately       call      your     gas
        supplier  from    a    neighbor’s
       phone.     Follow        the        gas
       supplier’s   instructions.
If     you     cannot    reach     your
        gas    supplier,    call      the    fire
      department.
C.  Use  only  your  hand  to  push  in
     or  turn  the   gas   control  knob.
     Never   use   tools.  If   the   knob
       will    not    push    in   or    turn    by
      hand, don’t  try  to  repair  it, call
     a qualified service technician or
      gas supplier. Force or attempted
        repair  may  result  in    a  fire  or
      explosion.
D.  Do not use this appliance if any
      part  has   been  under  w ater.
        Immediately    call    a    qualified
     service  technician   to   inspect
      the  appliance   and   to   replace
      any  part  of  the  control  system
     and any  gas control which has
      been  under  water.
Figure 16 -Checking  Gas  Joints