INSTALLATION
CONNECTING TO GAS SUPPLY
              WARNING:    A    qualified
service    person    must    connect
heater  to  gas  supply. Follow  all
local  codes.
           WARNING:  This  appliance
requires  a  3/8
"
  NPT  (National
Pipe  Thread)    inlet  connection
to  the  pressure  regulator.
          CAUTION:  Never  connect
h e a t e r     d i r e c t l y     t o       t h e
propane/LP  supply. This  heater
requires   an   external  regulator
(not     supplied).   Ins tall    t he
external  regulator  between  the
heater  and  propane/LP  supply.
*A  CSA/AGA  design-certified  equipment  shutoff  valve  with  1/8
"
  NPT  tap  is
an  acceptable  alternative  to  test  gauge  connection.  Purchase the  optional
CSA/ AGA    de s ign-c e rt if ied     equipm ent     s h ut off     v alv e    f rom
your  dealer.  See  Accessories,  page 17.
IMPORTANT:  Install  an  equipment
shutoff    valve    in    an    accessible
location.  The    equipment    shutoff
valve   is  for  turning  on  or  shutting
off  the  gas  to  the  appliance.
Install  sediment  trap  in  supply  line
as    shown    in    Figure  14.    Locate
sediment  trap  where  it  is  within
reac h      for    cleaning.    Locate
sediment      trap    where     trapped
matter  is  not  likely  to  freeze.  A
sediment   trap  traps  moisture  and
contaminants.  This     keeps  them
from  going  into  heater  controls.  If
sediment  trap  is  not  installed    or  is
installed    wrong,    heater    may
not  run  properly.
IMPORTANT:        Hold      pressure
regulator    w ith    wrenc h    w hen
connecting  it  to  gas  piping  and/or
fittings.
           CAUTION:   Use   pipe   joint
sealant    that    is    resistant    to
liquid  petroleum (LP)  gas.
Figure 14 -Gas  Connection
The   installer     must    supply    an
external    regulator.  The    external
regulator  will  reduce  incoming  gas
pr es s u re .   Yo u    m us t     r ed uc e
incoming  gas  pressure  to  between
11  and  14  inches  of  water. If  you
do    not    reduce    incoming    gas
pressure, heater  regulator  damage
c ould    oc c ur.   Inst all    external
regulator   with  the  vent   pointing
down    as    shown    in    Figure    13.
Pointing  the  vent  down  protects  it
from  freezing  rain  or  sleet.
Figure 13 - External  Regulator  with
                  Vent  Pointing  Down
       CAUTION: Use  only  new, black
iron  or steel  pipe.  Internally-tinned
copper  tubing   may   be   used   in
certain   areas.  Check   your   local
codes.  Use pipe  of  large   enough
diameter to allow proper gas volume
to  heater.   If    pipe   is   too   small,
undue loss of pressure  will occur.
Installation      must      include    an
equipment   shutoff   valve,   union,
and  plugged  1/8
"
 NPT  tap.  Locate
NPT tap within  reach  for  test  gauge
hook      up.      NPT    tap    must    be
upstream from heater(see Figure 14).
Apply  pipe  joint  sealant  lightly  to
male   threads.    This    will    prevent
excess    sealant   from    going    into
pipe.  Excess  sealant  in  pipe  could
result  in  clogged  heater  valves.
r
Typical Inlet Pipe Diameters
All  models  up  to  20,000 BTU’s  use
3/8’’ or greater pipe;
All models 25,000 BTU’s and higher,
use 1/2” or greater pipe.
WARING
:
Do not  over tighten gas
    connections.