INSTALLATION
Figure 8 - Mounting  Bracket
Clearances
Figure 7 - Removing  Lower Front
Panel  of  Heater
Figure  4 -Mounting  Clearances As
Viewed  From  Front  Of  Heater
Figure 5 - Moving Thermostat
Sensing Bulb
      IMPORTANT:      Vent-free
heaters   add   moisture   to     the
air.  Although  this  is  beneficial,
installing    heater    in    rooms
without    enough   ventilation    air
may   cause   mildew  to     form
from  too  much  moisture.  See
Fresh    Air    for  Combustion  and
Ventilation
,  pages  4 and 5.
FASTENING  HEATER  TO  WALL
Mounting  Bracket
The  mounting  bracket  is  located
on      back    panel    of    heater  (see
figure 6).  It  has  been  taped  there
for  shipping.  Remove  mounting
bracket  from  back  panel.
Removing  Lower  Front  Panel  Of
Heater.
1.   Remove  two  screws  near
      bottom  corners  of  front panel.
2.   Pull  bottom of  lower front  panel
      forward, then  down  (see Figure
      7).
Methods For  Attaching   Mounting
Bracket  To  Wall
Only  use  last  hole  on  each  end
of    mounting    bracket    to    attach
bracket   to  wall. These  two  holes
are    16    inches    apart    from  their
c e n t e r s .     A t t a c h     m o u n t i n g
bracket   to  wall  only in one of  two
ways:
1.    Attaching  to  wall  stud
2.    Attaching  to  wall  anchor
Attaching    to    Wall    Stud:    This
method    provides    the    strongest
hold.      Insert      mounting      screws
through    mounting    bracket    and
into  wall  studs.
Attaching  to    Wall  Anchor: This
method    allows    you    to  attach
mounting  bracket  to  hollow  walls
(wall  areas  between    studs)  or  to
solid   walls  (concrete  or  masonry).
Decide      which      method      better
suits  your  needs.  Either  method
will  provide  a  secure   hold  for  the
mounting  bracket.
Marking  Screw  Locations
1.  Tape  mounting  bracket  to  wall
where    heater    will    be    located.
Make    sure    mounting    bracket    is
level.
2.    Mark    screw    locations    on
wall. (see  Figure  8)
Note:    Only    mark    last    hole    on
each    end   of   mounting   bracket.
Insert   mounting  screws    through
these  holes  only.
3.      Remove    tape  and    mounting
bracket  from  wall.
            WARNING:       Maintain
minimum   clearances  shown  in
Figure  8.  If    you    can,    provide
greater   clearances   from   floor
and   joining   wall.
   Figure  6 -Mounting Bracket
                    Location
INSTALLING THERMOSTAT
SENSING BULB
For T-Stat  Models  Only
1. Pull out the sensing  bulb  from the
    two  clips  located  in  the  shippng
    position according to the direction
   as shown by the arrow. There is no
    need to take out  the two bulb clips.
2. Take  out  the  bulb  clip  from  the
     hardware package and insert  it into
      the square hole and then insert the
     sensing bulb into the bulb clip (see
     Figure 5).
         WARNING:   Maintain  the
minimum    clearances    shown
in     Fi gu re   4 .     If     yo u  c a n,
provide   greater   clearances   from
floor,   ceiling,  and   joining  wall.
Model  ML250HPA  ML250TPA
Model  ML150HPA    ML150TPA