Emerson Process Management 3400 用户手册

下载
页码 398
Meter setup and configuration worksheet
 Reference, Installation, and Operations Manual
June 2013
3-9000-743 Rev S
 323
Meter to Flow Computer Communication Worksheet
Hardware connection
RS-232
RS-485 Half Duplex 
(cannot be used for con-
nection to Daniel Meter-
Link)
RS-485 Full 
Duplex
Baud Rate
115200   57600   38400   19200   9600*   2400   1200
*Note: Start with a Baud rate of 9600 and test to see if higher or lower rates are acceptable.
Modbus Protocol
(auto-detected
by meter)
ASCII 7Even1
ASCII 70dd1
RTU 8None1
Serial Port B
User Selection (Circle one)
Results (Enter here) 
Connection to
<Flow computer,
RTU, etc.>
PC running Daniel 
MeterLink
Not used
Hardware connection
RS-232
RS-485 Half Duplex 
(cannot be used for con-
nection to Daniel Meter-
Link)
RS-485 Full 
Duplex
Baud Rate
115200   57600   38400   19200   9600*   2400   1200
*Note: Start with a Baud rate of 9600 and test to see if higher or lower rates are acceptable.
Modbus Protocol
(auto-detected by meter)
ASCII 7Even1
ASCII 70dd1
RTU 8None1
Serial Port C
User Selection (Circle one)
Results (Enter here) 
Connection to
<Flow computer, RTU, etc.>
PC running Daniel 
MeterLink
Not used
Hardware connection
RS-232
RS-485 Half Duplex 
(cannot be used for con-
nection to Daniel Meter-
Link)
RS-485 Full 
Duplex
Baud Rate
115200   57600   38400   19200   9600*   2400   1200
*Note: Start with a Baud rate of 9600 and test to see if higher or lower rates are acceptable.
Modbus Protocol
(auto-detected by meter)
ASCII 7Even1
ASCII 70dd1
RTU 8None1
Table E-2  Meter to Flow Computer Communication Worksheet  (Sheet 2 of 9)
Description