Figure 6 - Lineal Gain
LINEAL GAIN
PART NO.
DESCRIPTION
GAIN
Georgian
Fireplace
66 
1
/
"
12-12DM
12-12HT
Pipe Section
10 
5
/
8
"
18-12DM
18-12HT
Pipe Section
16 
5
/
8
"
24-12DM
24-12HT
Pipe Section
5
/
8
"
36-12DM
36-12HT
Pipe Section
34 
5
/
8
"
48-12DM
48-12HT
Pipe Section
46 
5
/
8
"
RLT-12D
RLT-12HT
Round Termination
3
/
4
"*
STL-12D
Square Chase-Top 
with Slip Section
7" to 15"*
* The lineal gain for the terminations is mea-
sured to the flue gas outlet height.
Hemmed 
End
3
/
8
Stainless 
Inner Pipe
15" Galvanized 
Outer Pipe
ASSEMBLY AND INSTALLATION OF 
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists of a 
galvanized outer pipe, a stainless steel inner flue 
pipe and a wire spacer. The pipe sections must be as-
sembled independently as the chimney is installed. 
When connecting chimney directly to the fireplace, 
the inner flue pipe section must be installed first 
with the lanced side up. The outer pipe section can 
then be installed over the flue pipe section with the 
hemmed end up. Press down on each pipe section 
until the lances securely engage the hem on the fire-
place starter. The wire will assure the proper spacing 
between the inner and outer pipe sections.
Continue to assemble chimney sections as outlined 
above, making sure that both the inner and outer 
pipe sections are locked together. When install-
ing double wall snap-lock chimney together, it is 
important to assure the joint between the chimney 
sections is locked. Check by pulling chimney 
upward after locking. The chimney will not come 
apart if properly locked. It is not necessary to add 
screws to keep the chimney together (exception, 
see Figure 9, page 8).
VenTing insTallaTion
OPTIONAL OUTSIDE AIR KIT 
(MODEL AK4/AK4F)
The installation of an outside air kit should be per-
formed during the rough framing of the fireplace 
due to the nature of it's location. Outside combus-
tion air is accessed through a vented crawl space 
(AK4F) or through a sidewall (AK4).
  CAUTION:  Combustion  air 
inlet  ducts  shall  not  terminate 
in attic space.
Figure 5 - Outside Air Kit
Secure to Collars with Metal Tape, 
Screws or Straps (Min. 1/4" x 20" size)
Air Inlet 
Location 
Must Allow 
For Bushes 
or Snow
Vent Hood 
Required for 
Wall Installation
Air Inlet 
Eyebrow
Vented Crawl Space
(Check Local Codes 
Before Installing in a 
Vented Crawl Space)
CHIMNEY PIPE
The DESA chimney system consists of 12", 18", 
24", 36" and 48" snap-lock, double-wall pipe 
segments,  planned  for  maximum  adaptability 
to individual site requirements. Actual lengths 
gained after fitting overlaps must be taken into 
consideration (lineal gain) and are given in the 
lineal gain chart (see Figure 6). Lineal Gain is the 
actual measurable length of a part after two or more 
parts are connected. For Canada, use chimney parts 
designated "HT".
 WARNING: The opening in the 
collar  around  the  chimney  at  the 
top  of  the  fireplace  must  not  be 
obstructed. Never use blown insula-
tion to fill the chimney enclosure.