页码 85
Fig. 8a
Fig. 8b
Fig. 8c
ON/OFF
operation button
LED CLEAN
LED CLEAN
ION
ION
TIMER
TIMER
OPR.
OPR.
(FILTER)
LED CLEAN lamp
ION lamp
(FILTER lamp)
TIMER lamp
OPERATION lamp
FILTER
RESET
RESET
TEST
ON 
/
 OFF
ON/OFF 
operation button
TEST RUN button
7-4.  How to Test Run the Air Conditioner
Use a sharp object when accessing ON/OFF and
TEST buttons in the indoor unit.
After turning on power to the air conditioner, use the
remote controller and follow the steps below to
conduct the test run.
(1) Either press the ON/OFF button on the indoor unit or use 
the remote controller to start the Air Conditioner. (Figs. 8a 
and 8b)
(2) Press and hold down the TEST RUN button on the indoor 
main unit controller until a beep is heard. At this time, all 
indicator lamps begin blinking.(Figs. 8a and 8c)
   If the outdoor unit has not started approximately 5 
minutes after the start of the test run, execute self 
diagnostics.
To execute self diagnostics, while the unit is stopped 
press and hold down the TEST RUN button until a beep 
is heard. Self diagnostics begins when the TEST RUN 
button is released.
(3) Press the ON/OFF operation button to end the test run. 
At this time, operation from the remote controller 
becomes possible.
IMPORTANT
26