Enviro EF3 用户手册

下载
页码 43
6
Operating Instructions
A
UTOMATIC
 S
AFETY
 F
EATURES
:
Your pellet Stove has the following safety features:
A. The  stove  will  shut  off  when  the  fire  goes  out  and  the  exhaust  temperature  drops  below  120°F 
(49°C).
B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F 
(93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature 
cools.  If this happens, call your local dealer to reset the 200°F (93°C) high limit switch. ALSO FIND 
THE REASONS WHY THE UNIT OVERHEATED.
C. The unit has a convection fan control over-ride.  This function causes the convection fan to reach its full 
speed when the temperature at the back of the firebox reaches 160°F (71°C).  This is a normal safety 
feature of your unit.  To compensate for the fan cycling action that may occur, turn up the blower 
control proportionately to the heat output.
D. If the power goes out, the unit will stop running.  When the power comes back on, the stove will not 
restart unless the exhaust temperature is still above 120°F (49 °C).
S
LIDER
/D
AMPER
 S
ETTING
:
����� ���� ���
������ �����
�� ���������
����� ��
��������
���� ����
������
�������� ���
Figure 1: Slider / 
damper positions.
The  slider/damper  must  be  set  at  time  of  installation.  This  is  used  to 
regulate the airflow through the pellet stove. The slider damper is located behind 
the left side panel. To open the left side panel, undo the one screw located in the 
upper front corner of the cabinet side
SPECIAL NOTES:
Pellet quality is a major factor in how the Pellet stove will operate. If the pellets 
have a high moisture content or ash content the fire will be less efficient and has a 
higher possibility of the fire building up and creating clinkers (hard ash build-up).
Circuit Board: If the fire should happen to go out and the heat output has been set 
on the lowest setting, use the auger trim button to increase feed rate or the Slider 
Damper should be pushed in slightly, decreasing the air in the firebox. Check the 
firebox vacuum and re-set if necessary.
Timer Control: If the fire should happen to go out and the Dial-A-Fire has been set 
on the lowest setting, the Slider Damper should be pushed in slightly, decreasing 
the air in the firebox or the Dial-A-Fire and Auger Trim can be turned up slightly.
If, after long periods of burning, the fire builds up and overflows the burn pot or 
there is a build up of clinkers, this would be a sign that the pellet quality is poor, 
this requires more primary air, the slider damper must be pulled out to compensate.  
Pulling the slider damper out gives the fire more air.
The easiest way to make sure that an efficient flame is achieved is to understand 
the characteristics of the fire.
•  A tall, lazy flame with dark orange tips, requires more air – Open slider (pull out) 
slightly.
•  A short, brisk flame, like a blowtorch, has too much air – Close slider (push in) 
slightly.
•  If the flame is in the middle of these two characteristics with a bright yellow/
orange, active flame with no black tips then the air is set for proper operation.