Enviro EF3 用户手册

下载
页码 43
Auger Trim
Auger Trim
Auger Trim
2 Seconds
"ON"
3 Seconds
"ON"
Factory Setting
4 Seconds
"ON"
1
1
1
4
5
 

 

 
3.  AUGER PULSE LIGHT: This light will flash in 
conjunction with the auger.
4.  MANUAL  AUGER  FEED:  If  the  unit  runs  out 
of  fuel,  this  button  can  be  used  to  “prime  the 
auger system”. This button will turn off after 60 
seconds and then must be released and pressed 
again.
5.  SYSTEM  LIGHT:  Responsible  for  signaling 
the  state  of  the  control  board.  When  the  light 
is  flashing  during  start-up,  the  stove  is  in  an 
automatic  start  mode.  When  the  light  is  solid, 
the Heat Level Setting can be altered.
6.  ON/OFF  BUTTON:  Used  to  turn  the  unit  ON 
and OFF.
7.  HEAT LEVEL INDICATOR: Shows the present 
heat output setting.
8.  HEAT LEVEL ADJUSTMENT: When pressed, 
will change the heat setting of the unit from low 
to high.
Operating Instructions
S
TOVE
 C
ONTROLS
 - C
IRCUIT
 B
OARD
:
1.  AUGER TRIM: The Auger Trim Button is used to increase or decrease the feed rate on LOW, ONLY. 
Push the Auger Trim button until the number 1 and 5 lights appear on the Heat Level Indicator.  This 
will increase the feed rate to 4 seconds ON time Auger pulse.  This is done only on LOW to allow the 
burning of poor quality fuels.  Push the button until the number 1 and 4 lights appear, this will reduce 
the Auger On time to 2 second.  This setting is for high-grade fuel only.  Push the button until just 
the number 1 light is on, this is for a three (3) second on time (standard setting).
2.  CONVECTION BLOWER CONTROL: Used to turn the convection blower ON/OFF.  If the blower 
is left off, and the sensor located on the air jacket reaches 160 °F (71 °C), the convection blower 
will  automatically  come  on  HI  speed  to  cool  the  unit.  Leave  the  convection  blower  ON  for  peak 
efficiency
Figure 2: Circuit board control panel. 
Figure 3: Auger trim  and heat level indicator. 