PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly 
against the ignitor tube for proper operation.  Check the hopper for enough pellets to start the unit.  
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN AJAR 
MANUAL MODE:
TO START:
 Press the ON / OFF button. The stove will turn on. The system light will flash. The Auger 
Light will flash with each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up). 
The Heat Level Indicator will show the Heat Level that the stove will run at after start-up.
If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to 
be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see 
“O
PERATING
 I
NSTRUCTIONS
; S
TOVE
 C
ONTROLS
”). 
TO OPERATE: When a fire has been established, the System Light will turn solid, the Auger Light will 
continue to flash to the corresponding Heat Level setting. The Heat Level button can now be pressed to 
change the desired Heat Level Output setting. 
The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting 
of the heat level output indicator. The convection blower can be turned OFF by depressing the convection 
blower control button. When the air jacket reaches 160 °F (71 °C) the convection blower will come ON 
High, cooling the unit. For the best efficiency and to prevent cycling, the convection blower should be 
left on at all times.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different 
quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the 
low setting is too hot for the room (see “O
PERATING
 I
NSTRUCTIONS
; S
TOVE
 C
ONTROLS
”). 
THERMOSTAT / SWITCH MODE:
INITIAL START-UP
:  See above
OPERATION - HI / LOW MODE:  When the thermostat contacts are closed the stove settings are 
adjustable as per Manual Mode (see above).  When the thermostat contacts open, the circuit board will 
take control of the settings. The stove will drop down to a low burn until the thermostat contacts close 
again. This low burn setting can be adjusted for different fuel qualities (see “O
PERATING
 I
NSTRUCTIONS
; S
TOVE
 
C
ONTROLS
”). The stove will come back to the previous HEAT LEVEL setting when the thermostat contacts 
close again.      
OPERATION – ON / OFF MODE:  When the thermostat contacts close, the unit will light automatically.  
Once  up  to  temperature,  the  stove  operates  the  same  as  in  manual  mode  (see  above).  When  the 
thermostat  contacts  open,  the  unit  automatically  begins  its  shutdown  routine.  The  stove  will  re-light 
when the thermostat contacts close again.
T
URNING
 Y
OUR
 P
ELLET
 S
TOVE
 O
FF
 - C
IRCUIT
 B
OARD
:
•  MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop 
the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, 
the stove will turn off.
•  ON / OFF mode: To turn the unit OFF, turn the thermostat down or off. 
DO NOT unplug unit while Combustion fan is operating.  
This may lead to smoke escaping from the stove.