Multiquip cx400 用户手册

下载
页码 34
cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) — page 21
Maintenance
Cleanup
1.  Wipe off any mud or debris that might have attached 
itself to the pump.
2.  If the pump was used to pump mud, grit or silt, flush  
vigorously with clean water.
3.  Store pump in a clean dry place away from dirt and 
debris.
lubrication
To check the lubrication oil level of the mechanical seal 
perform the following:
Checking Lubrication Oil Level (2,000 hours/6 months)
1.  Lay pump flat on its side (PX400 only) as shown in 
Figure 17.
Figure 17. Checking Lubrication Oil Level
2.  Using a screwdriver, remove oil plug.
3.  Visually inspect oil plug hole to verify that oil cavity is 
full enough to cover seal spring.
4.  When reinstalling oil plug, apply teflon tape to prevent 
leaking.
REMOVE
PACKING
REMOVE
OIL
PLUG
LAY PUMP FLAT
ON ITS SIDE
SUBMERSIBLE
PUMP
PX400
NOTICE
Refer  to  Figure  21  for  the  location  of  oil  plug.  for 
the  CX400  submersible  pump.  Pump  must  be  dis-
assembled to gain access to oil plug. When adding oil 
to the CX400 pump, pump must be turned upside down.
Changing Lubrication Oil (4,000 hours/12 months)
1.  If lubrication oil level is low, block the oil fill opening 
with a finger and lay pump on its side (Figure 18) to 
drain oil into a small container.
Figure 18. Draining Lubrication Oil
2.  Use a funnel (Figure 19) and fill oil cavity with Fluid 
Paraffin  P70  lubrication  oil  or  equavalent.  Pump  oil 
cavity capacity is 175 cc. Fill to 75-80% capacity to 
allow for expansion. Replace lubrication oil every 12 
months (4,000 hours) or as needed.
Figure 19. Adding Lubrication Oil