page 22 — cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) 
Inspecting Lubrication Oil (Mechanical Seal)
1.  Block the oil fill opening with a finger and roll pump to 
one side to drain (Figure 18) oil into a small transparent 
container.
2.  If  oil  is  cloudy  (milky)  or  has  water  in  it,  indicates 
that  mechanical  seal  is  defective  or  worn.  Replace 
mechanical seal.
impeller/mechanical Seal replacement (px400)
Reference the following procedure and Figure 20 for the 
removal of the impeller and mechanical seal.
1.  Remove the 4 bolts, nuts and washers that secure, 
casing cover to the casing..
Figure 20. Mechanical Seal Impeller 
Removal (PX400)
2.  Remove any debris that may have accumulated on 
the impeller.
3.  If  replacement  of  the  impeller  is  required,  remove 
impeller screw and washer.
4.  Slide mechanical seal from casing cover cavity and 
replace with new one.
5.  Replace  o-ring,  impeller  washer  and  conical  lock 
washer if necessary.
6.  Reassemble in reverse order.
REMOVE BOLTS
4 PLACES
MECHANICAL
SEAL
IMPELLER
IMPELLER
SCREW
REMOVE NUTS
4 PLACES
CASING
O-RING
IMPELLER
WASHER
CONICAL LOCK
WASHER
CASING
COVER
Maintenance
impeller/mechanical Seal replacement (cx400)
Reference the following procedure and Figure 21 for the 
removal of the impeller and mechanical seal.
1.  Remove  the  bolts  securing  the  casing  cover  to  the 
casing .
Figure 21. Mechanical Seal Impeller 
Removal (CX400)
2.  Remove any debris that may have accumulated on 
the impeller.
3.  If  replacement  of  the  impeller  is  required,  remove 
impeller nut and washer.
4.  Slide mechanical seal from casing cover cavity and 
replace with new one.
5.  Replace o-ring, impeller washer and washers, gaskets, 
oil seal and any other pump components if necessary.
6.  Reassemble in reverse order.