Chapter 4 Using the VB-99 in 
Combination with an FC-300
 
With an FC-300 (optional) connected to the VB-99, you can perform 
the following operations:
• Switch patches
• Have patch names be shown in the FC-300’s display
• Control tones with the FC-300’s pedals (Control Assign)
• Show the VB-99’s tuner in the FC-300’s display when the 
TUNER function is used
• Switch the FC-300’s Amp Control on and off
Connect the VB-99 and FC-300 using the RRC2 cable included with 
the unit.
 
What is RRC2?
 
RRC2 is a Roland protocol that provides for the supply of 
power and two-way data communications over a single cable.
Devices can also be connected using a commercially available 
ethernet cable instead of the included RRC2 cable.
 
• Be sure to connect the RRC2 OUT connector to a device with an 
RRC2 IN connector. Use of the connection with LAN or other 
devices may cause generation of heat and damage to the 
equipment.
• Carefully connect the RRC2 cable the way in—until it is firmly 
to the RRC2 IN connector.
• Do not subject the RRC2 cable to stress or physical shock.
• If using commercially available ethernet cable as the RRC2 
connecting cable, be sure that the cable meets the following 
specifications:
 
Category 5 (Cat5) or above
Maximum length of 15 meters
Cable designed for straight-through connection.
 
*
Ethernet cables designed for crossover connections cannot be used.
 
If connecting the VB-99 with an FC-300 using an RRC2 cable, make 
the settings below as needed.
This sets the method for controlling the FC-300.
 
1.
 
Press [SYSTEM].
 
2.
 
Press PAGE [
] to display Page 1.
 
3.
 
Press [F5] (FC-300).
 
4.
 
Set the SYS EX MODE with [F1] (OFF/ON) or 
with the F1 knob.
 
*
The FC-300 will not respond unless you return to the Play screen.
 
Connecting with the RRC2 
IN Connector
Settings Related to the FC-
300
 
Settings for Control of the FC-
300
 
Available 
Settings
Description
 
ON
When connected to the VB-99, the FC-300 automat-
ically changes to Exclusive mode and functions in 
accordance with the settings made with the VB-99. 
This is the setting normally selected. You can con-
trol the FC-300 even without matching the VB-99’s 
and FC-300’s Device IDs.
Connecting an FC-300 automatically switches the 
FC-300 to Exclusive mode. Normally, you should 
select this setting.
OFF
Select OFF when using the FC-300 in a mode other 
than System Exclusive mode.
The mode does not switch automatically.
VB-99_e.book 46 ページ 2008年8月18日 月曜日 午後1時10分