DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-775
ISDN-LNK (ISDN-PRI Signaling Link Port) 
10
Error Log Entries and Test to Clear Values
Notes:
a. Indicates that the circuit pack has been removed or has been insane for 
more than 11 minutes. To clear, reinsert or replace the circuit pack.
b. The actual alarming level depends on the options chosen via the 
set 
options
 command on the Manager terminal. ISDN-PRI Signaling Link Port 
alarms are treated as Station alarms, and their default alarming option is to 
downgrade all alarms to Warning. The value shown in the preceding table 
indicates the normal, unfiltered case (option "
y
" on the Set Options form).
c. ’pp’ is ’24’ for 24-channel interfaces, and ’16’ for 32-channel interfaces.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
NPE Crosstalk Test
, for example, you may also 
clear errors generated from other tests in the testing sequence. The command 
line entry to test the ISDN-LNK MO is: 
test port PCSSxx (sh or l)
, where ‘xx’ is 
‘24’ for 24-channel interfaces, and ‘16’ for 32-channel interfaces.
1.
Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Table 10-216.
ISDN-PRI Signaling Link Port Error Log Entries
Error 
Type
Aux 
Data
Associated 
Test
Alarm 
Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1 (c)
18
0
busyout port 
PCSSpp (c)
WARNING
OFF
release port PCSSpp (c)
130 (a)
None
WARNING
ON
test port PCSSpp sh (c)
1537 (b)
NPE Crosstalk 
Test #6
MINOR
ON
test port PCSSpp l r 3 (c)
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
NPE Crosstalk Test (#6)
X
ND
Signaling Link Board Check (#643)
X
X
ND