Q-Logic 8100 SERIES 用户手册

下载
页码 348
C–Brocade CEE/FCoE Switch/Blade Configuration
Verify that the Adapter is Logged into the Switch
FE0254601-00 A
C-7
Verify that the Adapter is Logged into the Switch
To verify that the switch has been properly configured and that the adapter has 
logged into the switch:
1.
List the devices that have logged into the switch by issuing the do fos 
fcoe command, and compare the device MAC/WWN with the information 
from the QLogic adapter port. In the example, vfc19 is logged into the switch 
and visible in the switch name server database.
(conf-if-te-0/19)# do fos fcoe --loginshow
================================================================================
Port   Te port        Device WWN             Device MAC        Session MAC
================================================================================
27     Te 0/19   10:00:00:00:c9:9c:c2:ef  00:00:c9:9c:c2:ef  0e:fc:00:01:1b:01
2.
List the name server database information by issuing the following 
command:
(conf-if-te-0/19)# do fos nsshow -t
{
 Type Pid    COS     PortName                NodeName                 TTL(sec)
 N    011b01;      3;10:00:00:00:c9:9c:c2:ef;20:00:00:00:c9:9c:c2:ef; na
    FC4s: IPFC FCP
    PortSymb: [34] "Emulex PPN-10:00:00:00:C9:9C:C2:EF"
    NodeSymb: [54] "Emulex OCe10102-FM FV2.701.462.1 DV7.2.32.002 APPS4082"
    Fabric Port Name: 20:1b:00:05:1e:d8:5f:80
    Permanent Port Name: 20:1b:00:05:1e:d8:5f:80
    Device type: NPIV Unknown(initiator/target)
    Port Index: 27
    Share Area: No
    Device Shared in Other AD: No
    Redirect: No
The Local Name Server has 1 entry 
3.
Configure zoning on the switch, as needed. For information about zoning the 
switch, refer to the Brocade switch documentation or DCFM documentation.
4.
Save the current switch configuration so that the configuration is persistent 
across switch reboots.
copy running-config startup-config