Chapter 19: LPC24XX SPI
7.3 SPI Data Register (S0SPDR - 0xE002 0008)
This bi-directional data register provides the transmit and receive data for the SPI. 
Transmit data is provided to the SPI by writing to this register. Data received by the SPI 
can be read from this register. When a master, a write to this register will start a SPI data 
transfer. Writes to this register will be blocked from when a data transfer starts to when the 
SPIF status bit is set, and the status register has not been read.
 
7.4 SPI Clock Counter Register (S0SPCCR - 0xE002 000C)
This register controls the frequency of a master’s SCK. The register indicates the number 
of SPI peripheral clock cycles that make up an SPI clock. 
In Master mode, this register must be an even number greater than or equal to 8. 
Violations of this can result in unpredictable behavior. The SPI0 SCK rate may be 
calculated as: PCLK_SPI / SPCCR0 value. The SPI peripheral clock is determined by the 
PCLKSEL0 register contents for PCLK_SPI.
In Slave mode, the SPI clock rate provided by the master must not exceed 1/8 of the SPI 
peripheral clock selected in 
. The content of the S0SPCCR register is not 
relevant. 
 
7.5 SPI Test Control Register (SPTCR - 0xE002 0010)
Note that the bits in this register are intended for functional verification only. This register 
should not be used for normal operation.
5
ROVR
Read overrun. When 1, this bit indicates that a read overrun has 
occurred. This bit is cleared by reading this register.
0
6
WCOL
Write collision. When 1, this bit indicates that a write collision has 
occurred. This bit is cleared by reading this register, then 
accessing the SPI data register.
0
7
SPIF
SPI transfer complete flag. When 1, this bit indicates when a SPI 
data transfer is complete. When a master, this bit is set at the 
end of the last cycle of the transfer. When a slave, this bit is set 
on the last data sampling edge of the SCK. This bit is cleared by 
first reading this register, then accessing the SPI data register.
Note:
 this is not the SPI interrupt flag. This flag is found in the 
SPINT register.
0
Table 463: SPI Status Register (S0SPSR - address 0xE002 0004) bit description
Bit
Symbol
Description
Reset Value
Table 464: SPI Data Register (S0SPDR - address 0xE002 0008) bit description
Bit
Symbol
Description
Reset Value
7:0
DataLow
SPI Bi-directional data port.
0x00
15:8 DataHigh
If bit 2 of the SPCR is 1 and bits 11:8 are other than 1000, some 
or all of these bits contain the additional transmit and receive 
bits. When less than 16 bits are selected, the more significant 
among these bits read as zeroes.
0x00
Table 465: SPI Clock Counter Register (S0SPCCR - address 0xE002 000C) bit description
Bit
Symbol
Description
Reset Value
7:0
Counter
SPI0 Clock counter setting.
0x00