Motorola MVME172 用户手册

下载
页码 354
4-42
Computer Group Literature Center Web Site
IP2 Chip
4
The registers which control IP_c and IP_d are not used on the 200/300-
Series MVME172. 
DMA Table Address Counter
In the command chaining mode, this counter should be loaded by the 
processor with the starting address of the list of commands. Note that the 
command packets in local bus memory must always be 16-byte aligned. 
That is, the starting address of any command packet must have the least 
significant nibble of the address set to a zero. If the Table Address Counter 
is initialized with a value where the four least significant bits are not a zero, 
the logic will interpret it as a halt condition and the command chaining 
process will not start. Therefore the entry in the last command packet 
which is loaded into the Table Address Counter should have one or more 
of these address bits set to a one to halt the command chaining process.
The registers which control IP_c and IP_d are not used on the 200/300-
Series MVME172. 
ADR/SIZ
$FFFBC030, $48, $60, $78 (32 bits each)
BIT
31...24
23
0
NAME
0
DMA_a Byte Counter
OPER
R
R/W
RESET
0 R
ADR/SIZ
$FFFBC034, $4C, $64, $7C (32 bits each)
BIT
31
...
0
NAME
DMA Table Address Counter
OPER
R/W
RESET
0 R