A template is provided with the cabinet isolation gasket. The template may be used to determine
the cable conduit locations. Place the template over the top of the PMF and align the top right
corner of the template with the top right corner of the PMF as shown in 
. The holes
punched in the template show the locations for the conduit within the PMF. 
Figure 3. Using the Template To Determine Duct Location Within the PMF
4
CONCRETE PAD CONSTRUCTION
Use the following procedure to construct the concrete pad:
1. Build a wood form for the concrete pad using 2 x 6 framing lumber as shown in 
2. Locate the PMF using the dimensions provided in the construction diagram (see 
).
When installed, the top surface of the PMF must be flush and level with the top of the
concrete pad. 
3. Place reinforcing material inside the form but outside of the PMF.
Note: Use temporary top framing to keep the top surface of the PMF flush and level with
the top of the concrete pad (see 
) while the concrete is poured. 
ALIGN EDGES OF 
TEMPLATE WITH 
EDGES OF PMF
CUT-OUT INDICATES
LOCATION OF FEEDER
CABLE CONDUIT
CUT-OUT INDICATES
LOCATION OF
DISTRIBUTION
CABLE CONDUIT
PLACE CARDBOARD
TEMPLATE OVER
TOP OF PMF
21937-A
FRONT OF
CABINET