five  times  doubling  the  thickness  with  each  fold.    After  the  fifth  fold,  place  the  thermocouple  tip  in  the  center  of  the 
aluminum piece and fold once more.  Finally, fold in the sides so that the foil clings to the thermocouple tip. 
 
A mercury thermometer can be weighted in much the same way by wrapping several layers of aluminum foil around 
the  bulb  end  thus  creating  the  necessary  mass.    This  procedure  is  a  must  if  you  open  an  oven  door  to  check 
temperature. 
 
THERMOSTAT OPERATION
 
 
It is normal for a hydraulic thermostat cycling with a temperature swing of 45° to 50°.  When checking  calibration first; 
allow  the  thermostat  to  cycle  a  minimum  of  four  (4)  times,  second;  place  your  temperature  sensor  in  the  geometric 
center of the empty oven.  Once the oven has been allowed to preheat record the temperature at which the burners 
cycle "ON and OFF".  Average the two readings, that average should be +-20° of the set point temperatu re. 
 
Example:    Thermostat  set  point  at  300°,    first  cycl e  Off  at  325°.    Cycle  back  ON  at 291°.  The average  of 325° and 
291° is 308°.  This thermostat is with the +-20° to lerance. If the thermostat is cycling beyond the 20° tolerance and the 
appliance is under warranty  recalibrate the thermostat or if not under warranty consult owner for proper action.  If 
the thermostat is out of calibration more than fifty 50
°
, it  will not likely hold an attempt of recalibration, we suggest that 
the thermostat be replaced. 
 
 
"B" Dial Shaft
"A" Calibration Screw Head
1/4" Turn
Increase
Decrease
 
 
- CALIBRATION NOTES -