InSinkErator AS-101K 用户手册

下载
页码 12
8
This control center was inspected and tested under 
operating conditions before shipment from the factory. 
In case of trouble, check the items listed below.
A.  Disposer motor will not start and water  
does not flow.
 
1.  No incoming line power, turn line power on.
  2.  Electric disconnect switch is not ON. Turn electric 
disconnect to ON position.
  3.  Electrical disconnect switch has been reactivated 
and 30-second delay has not yet expired. Wait 30 
seconds and try starting again.
  4.  Control circuit fuse FNA2 is blown. Replace fuse.
B.  Disposer motor stops while grinding but water 
continues to flow.
  1.  Control center wired for automatic shut-off. Press  
start button. If disposer runs for 10 minutes then 
shuts off, the automatic shutoff is active.  If the 
manual setting is desired, change as indicated in 
the feature section. 
  2.  Disposer is jammed. Press stop button and  
follow directions for unjamming that were  
supplied with the disposer.
3.  Disposer motor overload protector has tripped.
 
Follow instruction in C1.
C.  Disposer will not start but water flows.
1.  Overload protector on the disposer may have  
 
tripped. Press stop button. Locate red reset  
button on front of disposer electrical cover.  
Press to reset. If motor had been running, wait    
five minutes for the motor and overload to cool    
down before starting.
 
2.  Disposer is jammed. Press stop button and  
  follow directions for unjamming that were  
  supplied with the disposer.
PERSONAL INJURY
 • Allow only trained personnel to operate disposer.
 • Use baffles and guarding to avoid splashing and 
ejection of materials.
 • Do not put fingers or hands into the disposer.
 • When attempting to remove objects from a  
disposer, use long-handled tongs or pliers.
 • Turn power off before clearing a jam, removing  
an object from the disposer or pressing the  
red reset button.
PROPERTY DAMAGE
Use only an FNA2 replacement fuse. Using another 
replacement fuse will result in product damage.  
ELECTRICAL SHOCK/PROPERTY DAMAGE
 • Troubleshooting other than what is recommended 
in this section should only be performed by  
qualified service personnel.
 • Further troubleshooting performed by untrained 
personnel could result in electric shock or damage 
to the control center.
 • All electrical checks must be performed by a  
qualified professional.
Troubleshooting
D.  Water flows constantly before start button  
is pushed.
1.  Water solenoid valve is installed backward.  
  Water flow should be in the direction of the arrow  
  on valve.
E.  Water flow does not decease to 1 GPM.
1.  Incorrect solenoid valve combination 
connections. See Water Solenoid Valve, page 7.
2.  Incorrect trip point adjustment. See Current 
  Sensing Control Setup, page 8.
3.  Food load is present in disposer.
F.  Water flow does not increase.
1.   Insufficient food load is present.
2.   Incorrect trip point. See Current Sensing Control   
  Setup, page 8.
3.  Solenoid valve wiring incorrect in panel.
4.   More than two water solenoids wired into  
 
  system. System should have one solenoid with    
  a 1 GPM flow control and one solenoid with a  
  7 GPM flow control. 
NOTE: Use shutoff valves to adjust water flow for  
multiple trough or sink nozzles.
G.  Overload trips frequently.
1.   Do not overload disposer with excess amounts of  
  garbage and water (see disposer instructions for   
  recommended water flows).