This outdoor gas grill is not intended to be installed in or on recreational vehicles and/or
boats.
2.  
W
WA
AR
RN
NIIN
NG
G::    
Keep electrical supply cord and the fuel supply hose away from heated surfaces. 
3.  Keep grill area clear and free from combustible materials, gasoline, and other flammable vapors.
4.  When the outdoor grill is not in use, the gas supply must be turned off at the LP gas supply cylinder.
5.  The pressure regulator and hose assembly supplied with the outdoor grill must be used.  Replacement pressure
regulators and hose assemblies must be those specified by the manufacturer.
6.  Finding a leak is not a “do-it-yourself” procedure.  Some leaks can only be found with the burner control in the on
position and this must be done by a qualified technician.
7.  The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP-
gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres, and Tubes for the Transportation of Dangerous Goods.
8.  Gas Manifold Pressure - 
Natural gas - 4.0” W.C.P.
LP/Propane - 10.0” W.C.P.
9.  If the following instructions are not followed exactly, a fire causing death or serious injury may occur:
-Do not store a spare LP gas cylinder under or near this appliance.
-Never fill the cylinder beyond 80 percent full.
G
GA
AS
S  C
CO
ON
NN
NE
EC
CT
TIIO
ON
N
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the grill rating
plate agrees with that of the supply.  Never connect an unregulated gas line to the appliance.  An installer supplied gas
shut-off valve must be installed in an easily accessible location.  All installer supplied parts must conform to local codes,
or in the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI
Z223.1.  IIn
n  C
Caan
naad
daa::    Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation
Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes.  All pipe sealants must be an approved type
and resistant to the actions of LP gas.  Never use pipe sealant on flare fittings.  All gas connections should be made by
a competent technician and in accordance with local codes and or ordinances.  In the absence of codes, the installation
must comply with the National Fuel Gas Code ANSI Z223.1.  
The gas grill and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa).  The gas grill must be isolated from
the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system
at test pressures equal to or less than 1/2 psi (3.5 kPa).
G
GA
AS
S  C
CO
ON
NV
VE
ER
RS
SIIO
ON
N
To  convert the grill or oven from natural to LP/Propane or LP/Propane to natural, you MUST use the
designated conversion kit supplied by the manufacturer.  
For the T- Series grill:
-Use conversion kit TLPK-VGBQ to convert the unit from natural to LP.
-Use conversion kit TNK-VGBQ to convert the unit from LP to natural. 
For the T- Series grill with TruSear
TM
Infrared Grill Burner:
-Use conversion kit TLPK-VGIQ to convert the unit from natural to LP.
-Use conversion kit TNK-VGIQ to convert the unit from LP to natural. 
For the outdoor oven:
-Use conversion kit TLPK-BQCO to convert the unit from natural to LP.
-Use conversion kit TNK-BQCO to convert the unit from LP to natural.   