Extreme 10808 安装指南

下载
页码 186
MSM Module
 
Extreme Networks Consolidated XOS Hardware Installation Guide
119
Slots for the BlackDiamond 8810 MSM
If you are using only one G8X MSM in the BlackDiamond 8810 switch, install that MSM in slot 5. If you 
want to use two MSMs to increase reliability and throughput, install the second MSM in slot 6.
See 
 for information on how to 
install a G8X MSM.
Data Ports on the G8X MSM
The G8X MSM has eight SFP fiber mini-GBIC data ports. These ports operate the same as the ports on 
the G24X (see 
 for more information on these ports). 
The eight data ports are integrated into the MSM and managed by a separate I/O processor. This I/O 
subsystem CPU on the G8X MSM retains control of the eight Ethernet ports on the MSM during a 
failover. The backup MSM can take control of the ports.
NOTE
See the ExtremeWare XOS Concepts Guide and the ExtremeWare XOS Command Reference Guide for more 
information about numbering conventions for the modules and ports, as well as configuration and display 
information.
MSM Activity
The BlackDiamond 8810 switch can run with a single MSM installed. When you install an additional 
MSM, one of the MSMs operates as the primary, and the other becomes the secondary or backup.
The primary MSM is responsible for upper-layer protocol processing and system management 
functions. Packet handling is distributed among the CPUs of all installed MSMs.
When you save the switch configuration, it is saved to all MSMs.
Selection of the primary MSM occurs automatically. The following scenarios describe the selection 
process:
When the BlackDiamond 8810 switch boots with two MSMs already installed, the MSM in slot 5 
becomes the primary.
If an additional MSM is added to the switch after it has been powered-up, the added MSM becomes 
the secondary. MSMs that operate as secondary, or backup, MSMs can be inserted and removed 
without disrupting the network services.
If you remove the primary MSM while the BlackDiamond 8810 switch is operating, the secondary 
MSM experiences a soft reset and then becomes the primary MSM.
For example, if you have a BlackDiamond 8810 switch with a primary MSM in slot 5 and a 
secondary MSM in slot 6, and you remove the primary MSM from slot 5, the secondary, or backup, 
MSM in slot 6 becomes the primary.