Perform the final checks
Visual Inspection
After sealing the Case, check the sealing part of front and rear lid visually 
to confirm that the O-ring is not twisted or out of the groove and that no 
foreign matter has been caught. Also check that the Case is not broken or 
cracked.
Water Leakage Test
The final test after loading the camera is explained below. Always perform 
this test. It can be performed easily in a water tank or a bathtub. Confirm 
the operation of the different buttons. The required time is about 5 
minutes.
• At first, immerse the Case for only 3 seconds and check that no water 
drop etc. to the Case.
• Next, immerse the Case for 30 seconds and check that no water drop 
etc. to the Case.
• Then, immerse the Case for 3 minutes, operate all buttons and levers, 
and check the following:
- check that no water has accumulated the Case.
- check that the Case is not clouded.
- check that no water has entered the Case.
• If inside of the Case becomes cloudy or there is a water drop, do the 
maintenance of the O-ring and perform the water leakage test again.
CAUTION:
Hairs, fibers, and other narrow items are not very apparent, but they may 
cause water leakage. In addition, pay special attention to breaks and cracks 
on the Case.