Xerox DocuColor 12 Printer with Fiery EX12 产品宣传页

下载
页码 6
Finisher Local Faults
Fault
Fault Name
Action taken
Result
I attempted to cause the failure
by causing the belt that drives
the stapler head to come off as
the staple head was moving
from the Front Straight Sensor
to the Rear Straight Sensor on
a dual staple job.
I was successful at
preventing the Stapler form
reaching the Rear Straight
Sensor as indicated by the
fact that the print job only
had one staple in it, but the
012-249 fault code did not
show up on the web UI or on
the PWS. I did however get
the following fault codes on
the web UI: 012-246, 010-
900, 012-248, 001-300,
several 008-306, and 012-
245. The IOT UI seemed to
be locked up with the
following message: “Network
Print job is formatting. To
make copies, press
Interrupt. Connecting to
Network Controller. Printer
or Scanner is not ready.
Please wait.” Mick was able
to generate this fault code.
012-249
Stapler Rear
Straight
Sensor Fail
Unplugged J-1061A
Ran 2p., 3-copy, 2-staple long
edge job
½
  Plugged J-1061A back in &
ran job
á
 PO/PO’d 
m/c
No fault was displayed on
Copier UI. Print job
defaulted to finisher center
tray
Web UI – Fault History
shows 012-249; Status
shows 
Tray Output Needs
Attention.
½
  Job still defaulted to
Finisher center tray
½
  Web UI Fault History
then displayed 11-303
fault “ docking interlock
open
á
  Sent job w/ no problem
012-251
Set Clamp
Fault
Unplugged Set Clamp Sensor
Copier UI beeped 3 times &
displayed fault 012-251 but
not long enough to read
complete message (about 2
sec.) Staple job defaulted to
finisher center tray
PWS tool displayed 012-251
fault 
Set Clamp Fault in
Fault History
Web Fault History shows