Cisco Laser Link Ancillary Modules 安装指南

下载
页码 53
78-4028521-01 Rev B 
Setup and Operation 
3-13 
Alarm Tables,
 Continued 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
ELLT-3-14 
Laser Link full-
width 45-870 MHz, 
front panel optical 
connector, front 
panel slope and 
attenuator adjust 
controls 
#1/#5 
  
  
  
#2/#11 
#3/#12 
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Output Power 
Laser Bias Current  
Global Alarm – +5 V DC 
fails, laser temp ±5%, laser 
bias current ±20%, optical 
power – 25%, “A” supply 
fails 
0 V = normal 
+5 V = alarm 
  
  
1 V/mW 
1 V/50 mA 
24 V = normal 
0 V = alarm 
 
1550 nm Forward Transmitters Alarm Table 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
XMTR 
LEMT-P-10 
LEMT-S-10 
LEMT-I-10 
Laser Link single-
width transmitter, 
dual outputs 
#1/#15 
  
  
  
#2/#5 
#3/#6 
#4/#7 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Output Power 
Laser Bias Current  
Global Alarm – +5 V DC 
fails, laser temp ±5%, laser 
bias current ±20%, optical 
power – 25%, “A” supply 
fails, fan failure 
0 V = normal 
+5 V = alarm 
  
  
1 V/mW 
1 V/50 mA 
24 V = normal 
0 V = alarm