Cisco Laser Link Ancillary Modules 安装指南

下载
页码 53
3-14 
Setup and Operation 
78-4028521-01 Rev B 
Alarm Tables,
 Continued 
1310 nm Reverse Transmitters Alarm Table 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
XMTR  
5-200 MHz 
Laser Link II return 
transmitter, rear 
panel optical 
connector 
#1/#5 
  
  
  
#2 
  
#3/#12 
  
  
  
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
No connection on this 
module 
Laser Temp./Laser Bias – 
alarm when laser 
temperature or laser bias 
current is out of range 
Global Alarm – any above 
condition and +5 or -5 V 
DC fails 
0 V = normal 
+5 V = alarm 
  
  
No connection 
  
0 V = normal 
5 V = alarm 
  
  
24 V = normal 
0 V = alarm 
LLRT 
5-210 MHz 
Laser Link LLRT 5-
210 MHz return 
transmitter, front 
panel optical 
connector, rear panel 
fan 
#1/#5 
  
  
  
#2/#11 
#3/#12 
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Output Power 
Laser Bias Current  
Global Alarm – +5 V DC 
fails, laser temp ±5%, laser 
bias current ±20%, optical 
power – 25%, “A” supply 
fails 
0 V = normal 
+5 V = alarm 
  
  
1 V/mW 
1 V/50 mA 
24 V = normal 
0 V = alarm