Cisco Laser Link Ancillary Modules 安装指南

下载
页码 53
78-4028521-01 Rev B 
Setup and Operation 
3-15 
Alarm Tables,
 Continued 
Return Receivers Alarm Table 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
RCVR  
5-200 MHz 
Laser Link II full-
width receiver 
module, 5-200 MHz, 
rear panel optical 
connector 
#1/#5 
  
  
  
#2/#11 
  
#3 
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Receive Power 
Alarm (< -17 dBm) 
No connection 
Global Alarm – any above 
condition 
0 V = normal 
+5 V = alarm 
  
  
0 V = normal 
5 V = alarm 
No connection 
24 V = normal 
0 V = alarm 
LLRR 
5-210 MHz 
Laser Link half-
width 5-210 MHz 
return receiver, front 
panel optical 
connector 
#1/#5 
  
  
  
#2/#11 
#3/#12 
  
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Receive Power 
Loss of RF Alarm (< +18 
dBmV total power) 
Global Alarm – optical 
receive power < -17 dBm, 
“A” supply fails 
0 V = normal 
+5 V = alarm 
  
  
1 V/mW 
5 V = normal 
0 V = alarm 
24 V = normal 
0 V = alarm 
LLDR  
5-210 MHz 
Laser Link half-
width 5-210 MHz 
receiver, front panel 
optical connector 
#1/#5 
  
  
  
#2/#11 
#3 
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Receive Power 
No connection 
Global Alarm – optical 
receive power < -17 dBm, 
“A” supply fails 
0 V = normal 
+5 V = alarm 
  
  
1 V/mW 
No connection 
24 V = normal 
0 V = alarm