Cisco Laser Link Ancillary Modules 安装指南

下载
页码 53
3-16 
Setup and Operation 
78-4028521-01 Rev B 
Alarm Tables,
 Continued 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
ELLRR  
5-210 MHz 
Laser Link half-
width 5-210 MHz 
receiver, front panel 
optical connector 
#1/#5 
  
  
  
#2/#11 
#3 
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Receive Power 
No connection 
Global Alarm – optical 
receive power < -17 dBm, 
“A” supply fails 
0 V = normal 
+5 V = alarm 
  
  
1 V/mW 
No connection 
24 V = normal 
0 V = alarm 
 
Amplifier Modules Alarm Table 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
AMP/4 
  
  
 
AMP/FF 
  
  
AMP Dual 
Laser Link quad (4 
outputs) 
50-600 MHz and 
50-750 MHz 
Feedforward (single 
output) 50-550 MHz 
amplifier 
Laser Link dual amp 
(2 outputs), 
50-750 MHz and 
50-870 MHz 
#1/#5 
  
  
  
#2 
#3 
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
No connection 
No connection 
Global Alarm – “A” 
supply fails 
0 V = normal 
+5 V = alarm 
  
  
No connection 
No connection 
24 V = normal 
0 V = alarm